Affiliation:
1. 1 Poznan University of Technology , Department of Chemical Engineering and Equipment , 4 Berdychowo street, 60-965 Poznan
Abstract
Abstract
The use of a liquid level sensor made it possible to measure changes in gas hold-up over time in a stirred tank during unsteady mixing. These results were subjected to Fourier time series analysis and a model of gas hold-up changes in time was proposed. It allowed one to determine the model value of gas hold-up, which can be useful for characterizing gas hold-up during unsteady mixing and as a comparison to gas hold-up during steady mixing. The characteristic frequency was also determined, which corresponds to about twice the oscillation frequency. Model gas hold-up values for coalescing and non-coalescing systems were compared. Moreover, the change of the gas hold-up at constant maximum stirrer rotation frequency and variable gas flow rate for different oscillation frequencies was investigated.
Subject
General Chemical Engineering,General Chemistry,Biotechnology
Cited by
1 articles.
订阅此论文施引文献