The Importance of ECG Offset Correction for Premature Ventricular Contraction Origin Localization from Clinical Data

Author:

Svehlikova Jana1,Pribilova Anna1,Zelinka Jan1,Ondrusova Beata12,Kromkova Katarina3,Hlivak Peter3,Hatala Robert3,Tysler Milan1

Affiliation:

1. Institute of Measurement Science, Slovak Academy of Sciences , Department of Biomeasurements , Dubravska cesta 9 , Bratislava , Slovakia

2. Faculty of Electrical Engineering and Information Technology , Slovak University of Technology in Bratislava , Ilkovičova 2961 , Bratislava , Slovakia

3. National Institute for Cardiovascular Diseases , Department of Arrhythmias and Cardiostimulation , Pod Krasnou horkou 1 , Bratislava , Slovakia

Abstract

Abstract In this study, the inverse solution with a single dipole was computed to localize the premature ventricular contraction (PVC) origin from long term multiple leads ECG measurements on fourteen patients. The stability of the obtained results was studied with respect to the preprocessing of signals used as an input to the inverse solution and the complexity of the torso model. Two methods were used for the baseline drift removal. After an averaging of the heartbeats, the influence of the retention or elimination of the remaining offset at the beginning of the PVC signal was examined. The inverse computations were performed using both homogeneous and inhomogeneous patient-specific torso models. It was shown that the remaining offset in the averaged signals at the beginning of the PVC signal had the most significant impact on the stability of the resulting position within the ventricles. Its elimination stabilizes the location of the results, decreases the sensitivity to the torso model complexity and decreases the sensitivity to the primary baseline drift removal method. The additional offset correction decreased the mean distance between the results for all patients from 17-18 mm to 1-2 mm, regardless of the baseline drift removal method or the torso model complexity.

Publisher

Walter de Gruyter GmbH

Subject

Instrumentation,Biomedical Engineering,Control and Systems Engineering

Reference25 articles.

1. [1] Cluitmans, M.J.M., Peeters, R.L.M., Westra, R.L., Volders, P.G.A. (2015). Noninvasive reconstruction of cardiac electrical activity: Update on current methods, applications and challenges. Netherlands Heart Journal, 23 (6), 301–311. https://doi.org/10.1007/s12471-015-0690-9444628225896779

2. [2] Zhou, S., Sapp, J.L., AbdelWahab, A., Šťovíček, P., Horáček, B.M. (2018). Localization of ventricular activation origin using patient -specific geometry: Preliminary results. Journal of Cardiovascular Electrophysiology, 29 (7), 979–986. https://doi.org/10.1111/jce.1362229702740

3. [3] Van Dam, P.M., Tung, R., Shivkumar, K., Laks, M. (2013). Quantitative localization of premature ventricular contractions using myocardial activation ECGI from the standard 12-lead electrocardiogram. Journal of Electrocardiology, 46 (6), 574–579. https://doi.org/10.1016/j.jelectrocard.2013.08.00524028996

4. [4] Guillem, M.S., Climent, A.M., Rodrigo, M., Hernandez-Romero, I., Liberos, A., Fernandez-Aviles, F., Berenfeld, O., Atienza, F. (2016). Noninvasive identification of atrial fibrillation drivers: Simulation and patient data evaluation. Computing in Cardiology, 43, 121–124. http://dx.doi.org/10.22489/CinC.2016.039-42010.22489/CinC.2016.039-420

5. [5] Zemzemi, N., Dobrzynski, C., Bear, L.R., Potse, M., Dallet, C., Coudiere, Y., Dubois, R., Duchateau, J. (2015). Effect of the torso conductivity heterogeneities on the ECGI inverse problem solution. Computing in Cardiology, 42, 233–236. http://dx.doi.org/10.1109/cic.2015.740862910.1109/CIC.2015.7408629

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3