Development and Validation of an Automated Step Ergometer

Author:

C. de Sousa Maria do Socorro123,Aniceto Rodrigo R.124,Neto Gabriel R.125,T. de Araújo Ravi C.6,C. de Sousa Juliana B.17,Costa José A. D.8,Pellegrinotti Idico L.9

Affiliation:

1. Kinanthropometry and Human Performance Laboratory, Federal University of Paraíba, João Pessoa, Brazil

2. Physical Education Post-graduate Associate Program, Federal University of Paraíba, João Pessoa, Brasil

3. Laboratório de Cineantropometria e Desempenho Humano, Núcleo de Pesquisa em Ciências do Movimento Humano Universidade Federal da Paraíba, Sala 06, Castelo Branco, CEP: 58051-900, João Pessoa-PB, Brazil. Phone number: +55 83 99500577

4. Laboratory of Kinesiology and Biomechanics, Integrated Colleges of Patos, Patos, Brasil.

5. Physical Education Post-graduate Program, Federal University of Rio de Janeiro, Rio de Janeiro, Brasil

6. Kinanthropometry and Human Performance Laboratory, Federal University of Paraíba, João Pessoa, Brazil.

7. Physical Education Post-graduate Associate Program, Federal University of Paraíba, João Pessoa, Brasil.

8. Federal Institute of Education, Science and Technology of Paraiba, João Pessoa, Brazil.

9. Methodist University of Piracicaba, Piracicaba, Brazil.

Abstract

Abstract Laboratory ergometers have high costs, becoming inaccessible for most of the population, hence, it is imperative to develop affordable devices making evaluations like cardiorespiratory fitness feasible and easier. The objective of this study was to develop and validate an Automated Step Ergometer (ASE), adjusted according to the height of the subject, for predicting VO2max through a progressive test. The development process was comprised by three steps, the theoretical part, the prototype assembly and further validation. The ASE consists in an elevating platform that makes the step at a higher or lower level as required for testing. The ASE validation was obtained by comparing the values of predicted VO2max (equation) and direct gas analysis on the prototype and on a, treadmill. For the validation process 167 subjects with average age of 31.24 ± 14.38 years, of both genders and different degrees of cardiorespiratory fitness, were randomized and divided by gender and training condition, into untrained (n=106), active (n=24) and trained (n=37) subjects. Each participant performed a progressive test on which the ASE started at the same height (20 cm) for all. Then, according to the subject’s height, it varied to a maximum of 45 cm. Time in each stage and rhythm was chosen in accordance with training condition from lowest to highest (60-180 s; 116-160 bpm, respectively). Data was compared with the student’s t test and ANOVA; correlations were tested with Pearson’s r. The value of α was set at 0.05. No differences were found between the predicted VO2max and the direct gas analysis VO2max, nor between the ASE and treadmill VO2max (p= 0.365) with high correlation between ergometers (r= 0.974). The values for repeatability, reproducibility, and reliability of male and female groups measures were, respectively, 4.08 and 5.02; 0.50 and 1.11; 4.11 and 5.15. The values of internal consistency (Cronbach’s alpha) among measures were all >0.90. It was verified that the ASE prototype was appropriate for a step test, provided valid measures of VO2max and could therefore, be used as an ergometer to measure cardiorespiratory fitness.

Publisher

Walter de Gruyter GmbH

Subject

Physiology (medical),Physical Therapy, Sports Therapy and Rehabilitation

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3