A comparative assessment of the forces and moments generated at the maxillary incisors between conventional and self-ligating brackets using a reverse curve of Spee NiTi archwire

Author:

Sifakakis Iosif1,Pandis Nikolaos2,Makou Margarita1,Eliades Theodore3,Bourauel Christoph4

Affiliation:

1. * Department of Orthodontics, National and Kapodistrian University of Athens , Athens , Greece

2. † Private practice , Corfu , Greece

3. ± Department of Orthodontics, Aristotle University of Thessaloniki , Thessaloniki , Greece

4. + the School of Dentistry, Rheinische Friedrich-Wilhelms University of Bonn , Bonn , Germany

Abstract

Abstract Objectives To compare the intrusive forces and labio-palatal moments generated at the maxillary incisors by a 0.017 x 0.025 inch reverse curve NiTi wire using self-ligating and conventional brackets. Methods Ten 0.017 x 0.025 inch reverse curve NiTi archwires were used with each of the following 0.022 inch bracket systems: Titanium Ortho (Ormco/Sybron, CA, USA), In-Ovation R (GAC International, NY, USA) and Damon System 3MX (Ormco/Sybron, CA, USA). The wires were inserted on bracketed maxillary Frasaco models, with segmented maxillary incisors. Simulated intrusion from 0.0-1.0 mm was performed on the Orthodontic Measurement and Simulation System, which recorded the intrusive forces and the labio-palatal moments at 0.05 mm increments. The data were analysed with the ANOVA and Scheffe tests. Results The intrusive forces were significantly different between all bracket types. The highest force was recorded with the conventional Titanium Orthos brackets (8.2 N), followed by the Damon 3MX brackets (6.3 N) and the In-Ovation R brackets (5.5 N). The moments were found to be significantly different between the conventional and the self-ligating brackets, but not between the two types of self-ligating brackets. The highest moments were recorded with the self-ligating brackets (16.6-16.9 N/mm), followed by the conventional brackets (10.8 N/mm). Conclusions The intrusive forces exerted on the maxillary incisors by a 0.017 x 0.025 inch reverse curve NiTi archwire during the final 1 mm of levelling are very high and beyond the necessary intrusive force level for these teeth. Lower intrusive forces, but higher labio-palatal moments, were recorded with the self-ligating brackets.

Publisher

Walter de Gruyter GmbH

Subject

Orthodontics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3