Abstract The static magnetic field standard is part of many scientific experiments aimed at measuring the magnetic field. Often this device has to be built by oneself, if there is no possibility to buy it off the shelf. One possibility is also to convert a suitable device into a static magnetic field standard. Such a method is also described in this article. When the first experiments showed that the key parts could not be obtained under the existing conditions, it was decided to convert Bruker’s Minispec into a static magnetic field standard. Such a standard will not be completely universal, but it will accommodate many experiments, and the experience may help in the future when a more perfect standard is built. This article describes the design of the apparatus, briefly describing all the equipment, which includes many parts of the original device. The parts specific to the new construction are described in more detail. An alternative solution for frequency deviation calculation using a software quadrature detector, tested only in the form of a computer simulation, is also described.

Publisher

Walter de Gruyter GmbH

Subject

Instrumentation,Biomedical Engineering,Control and Systems Engineering

Reference14 articles.

1. Brigham, E. O. (1974). The Fast Fourier Transform. Prentice-Hall, ISBN 9780133074963.

2. Čížek, V. (1981). Discrete Fourier Transforms and their Applications. Prague, Czech Republic: SNTL, ISBN 9780852748008. (in Czech)

3. Andris, P., Dermek, T., Gogola, D., Přibil, J., Frollo, I. (2022). Analysis of NMR signal for static magnetic field standard. Measurement Science Review, 22 (2), 81-85. https://doi.org/10.2478/msr-2022-0010

4. Sundramoorthy, S. V., Epel, B., Halpern, H. J. (2017). A pulse EPR 25 mT magnetometer with 10 ppm resolution. Applied Magnetic Resonance, 48 (8), 805-811. https://doi.org/10.1007/S00723-017-0902-0

5. Keller, P. (2011). NMR Magnetometers. Magnetics Technology International, 68-71.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3