Diagnostic tests to assess balance in patients with spinal cord injury: a systematic review of their validity and reliability

Author:

Arsh Aatik1ORCID,Darain Haider1ORCID,Ullah Irfan2ORCID,Shakil-ur-Rehman Syed3ORCID

Affiliation:

1. Institute of Physical Medicine and Rehabilitation , Khyber Medical University , Peshawar , Khyber Pakhtunkhwa , Pakistan

2. Kabir Medical College , Gandhara University , Peshawar , Khyber Pakhtunkhwa , Pakistan

3. Riphah College of Rehabilitation and Allied Health Sciences , Riphah International University Lahore , Punjab , Pakistan

Abstract

Abstract Background Sophisticated biomechanical instruments can assess balance in patients with spinal cord injury (SCI) with accuracy and precision; however, they are costly and time consuming to use. Clinical diagnostic tests to assess balance in patients with SCI are less costly and easier to use, but there is limited literature available regarding their reliability and validity. Objectives To review systematically articles reporting the validity and reliability of diagnostic tests used to assess balance function in patients with SCI. Methods We searched for articles in the English language from the earliest record to December 15, 2020, which reported validity or reliability of any clinical instrument or diagnostic test used to assess balance in patients with SCI. Articles assessing balance in paraplegic patients with causes other than SCI were excluded. Databases included MEDLINE, AMED, EMBASE, HMIC, PsycINFO, CINAHL, Scopus, and Google Scholar. The COSMIN Risk of Bias checklist was used to assess the studies included and PRISMA-DTA guidelines were applied. Results We included 16 articles that assessed the validity or reliability of 10 diagnostic tests. The Functional Reach Test (FRT), Berg Balance Scale (BBS), and Mini-Balance Evaluation Systems Test (Mini-BESTest) were assessed by more than 1 study, while the remaining 7 diagnostic tests including the Function in Sitting Test, T-Shirt Test, Motor Assessment Scale item 3, Sitting Balance Score, 5 Times Sit-to-Stand Test, Tinetti scale, and Sitting Balance Measure were assessed by 1 study each. The FRT has good-to-excellent test–retest reliability, excellent inter-rater reliability, and good construct, concurrent, and convergent validity. The BBS has excellent inter-rater and intra-rater reliability, high internal consistency, and good concurrent and construct validity. The Mini-BESTest has excellent test–retest reliability, excellent inter-rater reliability, high internal consistency, and good concurrent, convergent, and construct validity. Conclusions The FRT, BBS, and Mini-BESTest appear to be valid and reliable clinical instruments to assess balance function in patients with SCI.

Publisher

Walter de Gruyter GmbH

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3