Affiliation:
1. University of Medicine and Pharmacy , Tîrgu Mureș , Romania
2. Center of Advanced Research in Multimodality Cardiac Imaging, Cardio Med Medical Center , Tîrgu Mureș , Romania
3. Cardiac Critical Care Unit, Clinic of Cardiology, County Clinical Emergency Hospital , Tîrgu Mureș , Romania
Abstract
Abstract
Background: Computed tomography angiography (CTA) presents important limits in in-stent restenosis (ISR) evaluation in case of metallic coronary stents, due to the artifacts determined by stent struts, which alter in-stent plaque analysis. In case of bioresorbable scaffolds, stent strut resorption allows accurate evaluation of the vessel wall. Aim of the study: This study aims to compare the feasibility of CTA as a follow-up imaging method for ISR diagnosis following elective PTCA procedures, between bioresorbable scaffolds and metallic coronary stents.
Material and methods: We conducted a prospective, observational study on 73 patients with elective PTCA procedures in their medical history, in whom 113 stents were assessed via CTA in order to diagnose ISR. Based on stent type, the patients were divided into two groups: Group 1 – patients with bioresorbable vascular scaffolds (BVS) (n = 30); and Group 2 – patients with bare metal stents (BMS) (n = 43). Plaque analysis was possible only in the BVS group with a post-processing research-dedicated software, Syngo.via Frontier, which identified plaque morphology and virtual histology composition.
Results: After CTA evaluation, the BVS group presented a significantly higher incidence of severe coronary artery disease (CAD) (Group 1 – 73% vs. Group 2 – 30%, p <0.0001). The proximal part of the right coronary artery (RCA) presented a significantly higher percentage of metallic stents (14% BMS vs. 2% BVS, p = 0.0029). The comparative analysis of CTA sensibility for the visual evaluation of ISR identified a significantly higher percentage of diagnostic CT evaluations in the BVS group (Group 1 – 94% vs. Group 2 – 76.19%, p = 0.0006). CTA evaluation provided the most accurate results for the 3.0 and 3.5 mm devices. Regarding CTA sensibility for ISR diagnosis, the BVS group presented the smallest incidence of non-diagnostic CT evaluations.
Conclusions: CTA evaluation of bioresorbable scaffolds is superior to metallic stent assessment, the latter being influenced by numerous sources of error dependent mainly on the presence of the metal structure.
Reference24 articles.
1. 1. Windecker S, Kolh P, Alfonso F, et al. 2014 ESC/EACTS Guidelines on myocardial revascularization. The Task Force on Myocardial Revascularization of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur Heart J. 2014;35:2541-2619.
2. 2. Ferent I, Mester A, Hlinomaz O, et al. Intracoronary Imaging for Assessment of Vascular Healing and Stent Follow-up in Bioresorbable Vascular Scaffolds. Current Medical Imaging Reviews. 2018. [Epub Ahead of Print.] doi : 10.2174/1573405614666180604093621.10.2174/1573405614666180604093621
3. 3. Gruntzig AR, Senning A, Siegenthaler WE. Nonoperative dilatation of coronary-artery stenosis: percutaneous transluminal coronary angioplasty. N Engl J Med. 1979;301:61-68.
4. 4. Sigwart U, Urban P, Golf S, et al. Emergency stenting for acute occlusion after coronary balloon angioplasty. Circulation. 1988;78:1121-1127.
5. 5. Roubin GS, Cannon AD, Agrawal SK, et al. Intracoronary stenting for acute and threatened closure complicating percutaneous transluminal coronary angioplasty. Circulation. 1992;85:916-927.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献