Typical air kerma area product values for trauma orthopaedic surgical procedures

Author:

Skrk Damijan1,Petek Katja2,Pekarovic Dean2,Mekis Nejc3

Affiliation:

1. Slovenian Radiation Protection Administration , Ljubljana , Slovenia

2. University Medical Centre Ljubljana , Ljubljana , Slovenia

3. Faculty of Health Sciences, University of Ljubljana , Ljubljana , Slovenia

Abstract

Abstract Background The aim of study was to establish the typical radiation quantity values for the most common trauma orthopaedic surgical procedures and to compare them with reference values of equivalent procedures performed in other institutions. In addition, we assess the impact of image intensifier and flat panel detector technology used for fluoroscopically guidance on patient exposure. Materials and methods Five most frequently performed fluoroscopically guided trauma orthopaedic procedures in University Medical Centre Ljubljana were analysed. Data on 199 cases over a 6 months period from December 2016 to June 2017 were gathered retrospectively. Study covered 40 dynamic hip screw fixations (DHS), 23 proximal femoral nail insertions (PFN), 20 proximal humeral nail insertions (PHN), 77 partial hip endoprosthesis implantations (PEP) and 39 percutaneous posterior spine fixations (PPS). The median and average along with the first and third quartile values of air kerma area product (KAP) for each procedure type were calculated as well as median and average value of fluoroscopy screening time. Results Typical KAP value for dynamic hip screw fixation was set at 0.52 Gycm2; for proximal femoral nail insertion at 0.53 Gycm2 and for proximal humeral nail insertion at 0.26 Gycm2. For implantation of partial endoprosthesis typical KAP value utilizing flat panel technology was set at 0.08 Gycm2 and at 0.21 Gycm2 when the image intensifier technology was used. Typical KAP value for percutaneous posterior spine fixation was set at 1.26 Gycm2, using flat panel technology and at 3.98 Gycm2 using image intensifier technology. Conclusions Established typical KAP levels of surgical orthopaedic procedures in traumatology will serve as a valuable tool for further radiation exposure optimization.

Publisher

Walter de Gruyter GmbH

Subject

Radiology Nuclear Medicine and imaging,Oncology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3