Comparison of three film analysis softwares using EBT2 and EBT3 films in radiotherapy

Author:

Pócza Tamás12,Zongor Zsuzsánna1,Melles-Bencsik Barbara1,Tatai-Szabó Dóra Zita1,Major Tibor13,Pesznyák Csilla12

Affiliation:

1. National Institute of Oncology, Centre of Radiotherapy , Budapest , Hungary

2. Budapest University of Technology and Economics, Institute of Nuclear Techniques , Budapest , Hungary

3. Department of Oncology, Semmelweis University , Budapest , Hungary

Abstract

Abstract Introduction The purpose of the study was to compare the results of gamma value based film analysis according to the used type of self-developer film and software product. Material and methods The films were irradiated with different treatment techniques such as 3D conformal and intensity modulated radiotherapy with static and rotational delivery. Stereotactic plans with conformal and intensity modulated arc techniques, using coplanar and non-coplanar beam setup were also evaluated. The data of irradiated film were compared with the planned planar dose distribution exported from the treatment planning system. Three film analysis software programs were evaluated: PTW Mephysto (PTW), FilmQA Pro (FQP) and radiohromic.com(RC). Both EBT2 and EBT3 types of films were examined. The comparisons of dose distributions were performed with gamma analysis using 10% cut-off level. Results The results of the gamma analysis for larger fields were between 78.3% and 98.3%, 75.7% and 100%, 80.2% and 98.8% with PTW, FQP and RC, respectively. The results of evaluation in case of stereotactic measurements were 76.8%–99.2% for PTW, 95.7%–100% for FQP and 91.2%–99.9% for RC. Conclusions All the three software programs are suitable for calibrating and evaluating films, performing gamma analysis, and can be used for patient specific quality assurance measurements. There is no direct connection between gamma passing rate and absolute accuracy or software quality, it is just a feature of the software. The interpretation of own results has to be defined on an institutional level according to given workflow and preliminary results.

Publisher

Walter de Gruyter GmbH

Subject

Radiology, Nuclear Medicine and imaging,Oncology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3