Introduction. Measurements of the amplitude-time characteristics of pulsed magnetic fields are required in various research and technology areas. Such measurements are carried out during pulsed magnetic field immunity testing, with the magnetic field pulse rise time being hundreds of ns, and the pulse duration to its half initial value (halfdroop) being hundreds of µs.Aim. To develop a meter of magnetic field strength with a linear conversion characteristic for measuring the pulse rise time, the pulse duration to its half-droop, and the peak value of the pulsed magnetic field strength.Materials and methods. Among several available methods for measuring pulsed magnetic field parameters, the induction method was selected. To obtain a signal proportional to the pulsed magnetic field strength, a signal from the induction transducer is integrated using a self-integrating induction transducer (RL integration) or by using an external RC integrator. The former method shows good results when measuring signals with a duration of hundreds of ns; however, this method is inefficient when measuring the parameters of longer-duration pulses. The latter method is used to determine the parameters of signals with a duration of hundreds of µs and ms; however, this method gives a large error when measuring the parameters of signals with a duration of hundreds of ns and less. The consecutive use of the two integration methods leads to an additional error in the measurement of the pulse duration to its half-drop.Results. A setup for determining the required magnetic field pulse parameters using a pulse magnetic field meter based on an RL integrator was developed. The relative measurement errors comprised 10, 10, and 9 %, respectively. The developed setup eliminates the error caused by losses in the active resistance of an induction transducer, thus enabling the pulse duration to its half-droop to be measured without additional errors under the pulse rise time of hundreds of ns and the pulse droop time of hundreds of µs.Conclusion. The development of a functional converter made it possible to extend the frequency response of a pulsed magnetic field meter based on an RL integrator to the low-frequency region.
Publisher
St. Petersburg Electrotechnical University LETI
Reference16 articles.
1. Balyuk N. V., Orlov S. D., Olenevsky V. V., Stetsyuk D. N. Requirements for the Stability and Resistance of Technical Systems to the Effects of Pulsed Electromagnetic Fields. Technologies of Electromagnetic Compatibility. 2022, no. 2 (81), pp. 3–19. (In Russ.)
2. Kuprienko V. M., Akomelkov G. A., Romantsov V. N., Orekhov N. M., Khlebnikov A. I. Test Technique and Results of Active Lightning-Conductor Protective Action. Proc. of the Russian Academy of Sciences. Power Engineering. 2015, no. 3, pp. 129–139. (In Russ.)
3. Gunyaeva A. G., Cherfas L. V., Komarova O. A., Kuprienko V. M. Carrying out Tests for Resistance to Lightnings of the Experimental and Constructive and Similar Samples Executed from Carbon Plastic, with Covering Protected from Lightnings. Proc. of VIAM. 2017, no. 7 (55), pp. 10. doi: 10.18577/2307-6046-2017-0-7-10-10 (In Russ.)
4. Skoblikov O., Kniaziev V. Penetration of Lightning Electromagnetic Pulses into Metallic Enclosures with Apertures. Electric Power Systems Research. 2014, vol. 113, pp. 48–63. doi: 10.1016/j.epsr.2014.03.014
5. Gormakov A. N., Ulyanov I. A. Calculation and Modeling of Magnetic Fields Generated By the System "Helmholtz Rings-Solenoid". Fundamental Research. 2015, no. 3, pp. 40–45. (In Russ.)
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Development of a Pulse Magnetic Field Meter;2024 XXVII International Conference on Soft Computing and Measurements (SCM);2024-05-22
2. Pulsed Magnetic Field Meter;2024 Conference of Young Researchers in Electrical and Electronic Engineering (ElCon);2024-01-29