Improvement of the Russian National Secondary Standard of the Unit of Length Using Latest Ultra-Stable Laser Equipment

Author:

Mosckalev Andrew A.1ORCID,Rahman Ardi2ORCID

Affiliation:

1. D.I. Mendeleyev Institute for Metrology "VNIIM"

2. National Standardization Agency – BSN; Saint Petersburg Electrotechnical university

Abstract

Introduction. Increasing demands of precise geometry measurements by science and industry cause the necessity of improvement in an associated branch of legal and practical metrology. One of the most significant fields is the measurement of internal dimensions and so the issues with the unit of meter transfer. Now we face the situation when the current accuracies of National standards of different levels in corresponding traceability chain (reference rings measurements) get close to each other. This means that we have to make the standard of upper level more precise. One of the obvious ways is to apply the latest ultra-stable laser locked to a frequency comb.Objective. The objective is to propose possibilities for improvement of the National secondary standard of the unit of length by researching its measuring capabilities to minimize measurement uncertainty.Materials and methods. The calculation of expanded uncertainty of internal diameter measurements by the National secondary standard of the unit of length is performed according to the international document «Guide to the Expression of Uncertainty in Measurement» JCGM 100:2008 approved by BIPM. The secondary standard research results represented in previous reports and publications are also taken into consideration.Results. Detailed uncertainty budget for the proposed measuring system is given as well as graphical data representing the accuracy improvement.Conclusion. Actions for minimization of measurement uncertainty components of the National secondary standard of the unit of length in the field of reference ring internal diameter measurements in combination with state-of-the-art laser interferometer system improve it to the next frontiers of accuracy and precision.

Publisher

St. Petersburg Electrotechnical University LETI

Reference16 articles.

1. Rosstandart order № 2840 dated 29.12.2018. Submission of the State Verification Schedule for Measuring Instruments in the Range of Length from 1•10-9 to 100 m and Wavelength in the Range of 0.2 to 50 μm. Available at: https://www.gost.ru/portal/gost/home/activity/documents/ orders#/order/75693 (accessed 17.08.2019). (In Russ.)

2. GOST R 8.763-2011. State System for Ensuring Uniform Measurement. State Verification Schedule for Measuring Instruments in the Range of Length from 1•10-9 to 50 m and Wavelength in the Range of 0.2 to 50 μm. Moscow, Standardinform, 2013, 8 p. (In Russ.)

3. Bourdun G. D., Markov B. N. Metrology Basics. Moscow, Standards Publishing, 1985, 256 p. (In Russ.)

4. Farago F. T., Curtis M. A. Handbook of Dimensional Measurement. NY, Industrial Press Inc., 1994, 580 p.

5. Rahman A., Mosckalev A. Reducing Uncertainty of Standard Reference Ring Measurement Up to 50 nm by Means of Non-Contact Method. Proc. SPIE Optics + Optoelectronics. Prague, Czech Republic, 2019. doi: 10.1117/12.2520381

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3