Abstract
Supplemental dampers are a means of repeatedly dissipating energy without damage to the underlying structure, increasing life-safety and helping provide better serviceability of structures following a major earthquake. High performance (small size) lead dampers are designed and tested to characterise their force-displacement behaviour and produce trade-off curves relating device geometry to force capacity, to parameterise the design space to enable further devices to be designed for structural applications. Peak forces of 120-350 kN were obtained for devices that were all able to fit within standard structural connections. Results show that prestressing the working material is critical to obtain optimal energy dissipation. Although previously characterised as extrusion dampers it is shown that classical extrusion modelling formulations do not strictly work well for this class of damper. Instead a coulomb type of stress-based model is proposed, with relationships presented that are independent of device scale. Empirical reduction factor equations are applied to the New Zealand Structural Design Actions to enable lead extrusion devices to be incorporated into structural design analyses. The overall results indicate that repeatable, optimal energy dissipation can be obtained in a compact device to minimise damage to critical buildings and infrastructure.
Publisher
New Zealand Society for Earthquake Engineering
Subject
Geotechnical Engineering and Engineering Geology,Civil and Structural Engineering
Cited by
22 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献