Defining the Cortical Purchase Zone in New Minimally Invasive Bunion Surgery. A Retrospective Study of 638 Cases.

Author:

Blitz Neal M.1ORCID,Grecea Bogdan1ORCID,Wong David T.2ORCID,Baskin Eric S.3ORCID

Affiliation:

1. Blitz Footcare

2. Bronx-Lebanon Hospital Center

3. Advocare Stafford Orthopedics

Abstract

Introduction The stability of the screws in the cortical purchase zone (CPZ) with new minimally invasive bunion surgery (MIBS) is of utmost importance in creating a stable construct for maintaining position and providing a scaffold for bone healing. The distance between the osteotomy and where the screw(s) exit the lateral cortex (a distance we herein coin the “Cortical Runway”) within the CPZ has yet to be studied, and is the focus of this retrospective study. Methods A retrospective review was preformed of a single surgeons first and consecutive cases of patients who had undergone MIBS from January 2018 to November 2022. The CPZ measurement was obtained on early postoperative radiographs. The CPZ was divided into five stability regions using the statistical empirical rule to define the boundaries of each of the regions. Results We included 427 patients and 638 feet in this study. Radiographic measurements were performed at an average 20.7±24.2 days (95% CI, 15.3–15.8 days) from surgery. The mean age of the patients was 46.5±15.0 years (95% CI, 45.3–47.6 years). There were 330 (51.7%) right feet and 308 (48.3%) left feet. Of the 427 patients, 211 (49.4%) had surgery on both feet, with 97 (46%) having both feet operated on the same day. A 1-screw construct was performed in 526 feet (82.4%) and a 2-screw construct in 112 feet (17.6%) of the total 638 feet. The mean anchor screw (primary screw) distance was 10.4±3.7mm (95% CI, 10.1-10.7mm). The mean collateral screw (secondary screw) distance was 1.2±2.0mm (95% CI, 0.8-1.5) and the mean cortical bridge (distance between the two screws) was 10.3±3.2mm (95% CI, 9.7-10.9), in 112 feet. We were able to define the CPZ stability region boundaries, which are: danger (< 2.9mm), vulnerable (3.0 - 6.6mm), standard (6.6 - 14.1mm), safety (14.2 - 17.8mm) and the security (> 17.9mm). Conclusion These CPZ boundaries and newly delineated stability regions will serve not only as an intraoperative visual tool for surgeons to perform MIBS successfully, but will also provide a much more stable and safer construct, thus minimizing risks and complications.

Publisher

Voom Medical Devices, Inc

Reference25 articles.

1. Patterns of Metatarsal Explosion After New Modern Minimally Invasive Bunion Surgery. A respective Review and Case Series of 16 Feet;N.M. Blitz;Journal of Minimally Invasive Bunion Surgery,2024

2. Revcon™ Minimally Invasive Screw System Surgical Technique;Voom Medical Devices, Inc,2023

3. Third-generation minimally invasive Chevron and akin osteotomies (MICA) in Hallux Valgus surgery;Thomas L. Lewis;J Bone Joint Surg Am,2021

4. Percutaneous Surgery of the Forefoot;David Redfern;Clinics in Podiatric Medicine and Surgery,2015

5. Minimally invasive chevron Akin (MICA) for correction of hallux valgus;David Redfern;Tech Foot Ankle Surg,2016

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3