Electropolymerization of Aminoanthraquinone from H2SO4/Acetonitrile Mixed Solvent – Polymer Film Characterization and its Use as Analytical Sensor

Author:

Badawy Waheed A.1,Ismail Khaled M.1,Medany Shymaa S.1

Affiliation:

1. Chemistry Department-Faculty of Science-Cairo University, 12613 Giza, Egypt

Abstract

Abstract Polyaminoanthraquinone, PAAQ, films were prepared potentiodynamically and potentiostatically from acetonitrile/sulfuric acid mixed solvent. Series of investigations have been carried out in which the mixed solvent ratio, type of substrate, electrochemical technique, potential scan range, scan rate and number of cycles were investigated in order to optimize the electropolymerization process. The potentiodynamic technique using glassy carbon, GC, substrates provides more stable films and useful information about the electropolymerization process from the mixed solvent. The suitable monomer concentration was 5.0 mM of 1-amino-9, 10-anthraquinone dissolved in 4.0 M H2SO4/ACN mixed solvent with a volume ratio 7:3. The most suitable potential scan range was from − 0.5 to + 1.4 V at a scan rate of 100 mV s 1. The effect of the scan repetition i. e. the thickness of the prepared polymer films on the electroanalytical performance of the modified electrode was investigated and discussed. The kinetics of electropolymerization process was investigated and the reaction was found to be first order with respect to the monomer concentration and of negative order with respect to sulfuric acid. The formed films were used successfully as analytical sensors for ascorbic acid, catechol, Ce III ions, dopamine, epinephrine, p-aminophenol and pyrogallol. The determination is based on the construction of a calibration curve for each analyte using the values of the oxidation peak currents in the cyclic voltammogram obtained by the PAAQ modified electrode in each case. The data were compared with the data obtained previously by the same films prepared in non-aqueous and aqueous media. The significance of the analytical performance of the formed films with respect to the state-of-the-art was investigated and discussed. The use of the mixed solvent, beside its effectiveness as analytical sensor, has limited the effect of hazardous organic solvent.

Publisher

Walter de Gruyter GmbH

Subject

Physical and Theoretical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3