Affiliation:
1. Department of Pediatric Surgery, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung, Taiwan
Abstract
Background Various techniques for laparoscopic insertion of a peritoneal dialysis catheter have been described. Usually 2 – 3 ports are required, and complications related to the port sites (such as abdominal wall hernia, leakage, and hemorrhage) cannot be avoided. To minimize the potential complications, we designed a simplified 1-port laparoscopic technique for peritoneal dialysis catheter placement. Methods We conducted a retrospective data review of 44 patients who underwent 1-port laparoscopic insertion of a Tenckhoff catheter from June 2009 to February 2011. All patient data, including postoperative complications, were analyzed. Results The mean follow-up period was 11.52 months. All catheters were working properly, except in 1 patient who developed peritonitis 3 months after catheter placement. (The catheter was removed.) No postoperative abdominal wall hemorrhage, early leaks, hernias, or catheter migration occurred. No exit-site or tunnel infections were observed. Conclusions Our 1-port laparoscopic technique provides excellent catheter fixation, avoids excessive port sites, and yields good cosmesis. The low complication rate and the simplicity of the method justify its standard use for Tenckhoff catheter placement.
Subject
Nephrology,General Medicine
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献