Compatibility of Meropenem with Different Commercial Peritoneal Dialysis Solutions

Author:

Wiesholzer Martin1,Winter Alexandra2,Kussmann Manuel3,Zeitlinger Markus4,Pichler Petra1,Burgmann Heinz3,Reznicek Gottfried2,Poeppl Wolfgang35

Affiliation:

1. Department of Internal Medicine I, Medical University of Vienna, Austria

2. University hospital St. Poelten, Karl Landsteiner University of Health Sciences, St. Poelten, Austria; Department of Pharmacognosy, Medical University of Vienna, Austria

3. University of Vienna, Vienna, Austria; Department of Internal Medicine I, Medical University of Vienna, Austria

4. Division of Infectious Diseases and Tropical Medicine, Medical University Vienna, Vienna, Austria; Department of Clinical Pharmacology, Medical University of Vienna, Austria

5. Medical University Vienna, Vienna, Austria; Department of Dermatology, Medical University of Vienna, Austria

Abstract

BackgroundIntraperitoneal administration of antimicrobial agents is recommended for the treatment of peritoneal dialysis (PD)-related peritonitis. For home-based antimicrobial therapy it is common to supply patients with PD fluid bags with admixed antibiotic. Thus, the compatibility of meropenem with different PD fluids (PDFs), namely Extraneal, Physioneal 1.36% and Physioneal 2.27% (all Baxter Healthcare Corp., Deerfield, IL, USA), was investigated under varying storage conditions.MethodsMeropenem (Venus Pharma, Werne, Germany) was stored at 6°C and 25°C over 14 days and at 37°C over 24 hours. Drug concentration over time was determined using high performance liquid chromatography, drug activity by a diffusion disk method, diluent stability by visual inspection and drug adsorption was calculated. Blank PD fluids and deionized water were used as comparator solutions.ResultsCompared to water, the stability of meropenem was minimally lower in Extraneal but markedly reduced in both Physioneal solutions. No significant drug adsorption was detected for any PDF investigated.ConclusionsMeropenem is stable and compatible with Extraneal and might be stored for up to a week at refrigeration temperature (6°C). A loss of ∼20% of meropenem after 2 days at room temperature should be considered. Mixed Physioneal appears not suitable for storage at any temperature after meropenem has been admixed. A considerable drug degradation due to the warming up to body temperature through heating plates should further be taken into account in clinical practice.

Publisher

SAGE Publications

Subject

Nephrology,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Stability and compatibility of intraperitoneal antimicrobials in peritoneal dialysate solutions;Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis;2023-09-20

2. Culture-directed antibiotics in peritoneal dialysis solutions: a systematic review focused on stability and compatibility;Journal of Nephrology;2023-08-07

3. Compatibility of aztreonam in four commercial peritoneal dialysis fluids;Scientific Reports;2020-02-04

4. Stability of Meropenem and Piperacillin/Tazobactam with Heparin in Various Peritoneal Dialysis Solutions;Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis;2018-11

5. Compatibility of linezolid with commercial peritoneal dialysis solutions;American Journal of Health-System Pharmacy;2018-10-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3