The Beneficial Influence on the Effectiveness of Automated Peritoneal Dialysis of Varying the Dwell Time (Short/Long) and Fill Volume (Small/Large): A Randomized Controlled Trial

Author:

Fischbach Michel1,Issad Belkacem2,Dubois Vincent3,Taamma Redouane3

Affiliation:

1. Nephrology Dialysis Transplantation Children's Unit, University Hospital Hautepierre, Strasbourg

2. Nephrology, Pitié–Salpétrière, Paris

3. Fresenius Medical Care–Nephrocare France, Fresnes, France

Abstract

Background It is well known that the efficiency of peritoneal dialysis (PD) varies with the duration of the dwell and with the prescribed fill volume. Automated PD (APD) is classically given as a series of recurrent exchanges, each having the same dwell time and fill volume—that is, conventional APD (APD-C). We propose a new way of giving PD, using a modified version of APD-C. This method first uses a short dwell time with a small fill volume to promote ultra-filtration (UF) and subsequently uses a longer dwell time and a larger fill volume to promote removal of uremic toxins from the blood. We use the term “adapted APD” (APD-A) to describe this modified form of PD. Methods We designed a multicenter prospective randomized crossover trial to assess the impact of APD-A in comparison with APD-C on the efficacy of dialysis. The parameters investigated were overnight UF; weekly peritoneal Kt/Vurea; weekly peritoneal creatinine clearance corrected to 1.73 m2 body surface area (Kcreat); and phosphate (PDR) and sodium dialytic removal (SDR) in millimoles per session, corrected for glucose absorption, which provides an estimate of metabolic cost. Blood pressure was also regularly monitored. Initially, 25 patients were identified for inclusion in the study. There were 6 withdrawals in total: 2 at enrolment, 1 at day 75 (transplantation), 2 at day 30 (catheter dysfunction), and 1 for drainage alarms. All patients received the same duration of overnight APD, using the same total volume of dialysate, with the same 1.5% glucose, lactate-buffered dialysate (Balance: Fresenius Medical Care, Bad Homburg, Germany). Results Tolerance was good. Compared with APD-C, APD-A resulted in a significant enhancement of Kt/Vurea, K creat, and PDR. The metabolic cost, in terms of glucose absorption, required to achieve dialytic capacity for urea, creatinine, and phosphate blood purification was significantly lower for APD-A than for APD-C, and UF increased during APD-A. With APD-A, each gram of glucose absorbed contributed to 18.25 ± 15.82 mL UF; in APD-C, each gram of glucose absorbed contributed to 15.79 ± 11.24 mL UF. However, that difference was not found to be significant ( p = 0.1218). The SDR was significantly higher with APD-A than with APD-C: 35.23 ± 52.00 mmol and 18.35 ± 48.68 mmol per session respectively ( p < 0.01). The mean blood pressure recorded at the end of each PD period (on day 45) was significantly lower when patients received APD-A than when they received APD-C. Conclusions Our study provides evidence that, compared with the uniform dwell times and fill volumes used throughout an APD-C dialysis session, the varying dwell times and fill volumes as described for an APD-A dialysis session result in improved dialysis efficiency in terms of UF, Kt/Vurea, K creat, PDR, and SDR. Those results were achieved without incurring any extra financial costs and with a reduction in the metabolic cost (assessed using glucose absorption).

Publisher

SAGE Publications

Subject

Nephrology,General Medicine

Cited by 49 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3