Reliability of intracortical inhibiton measured using threshold tracking technique

Author:

Bakulin I. S.1ORCID,Zabirova A. Kh.1ORCID,Poydasheva A. G.1ORCID,Sinitsyn D. O.1ORCID,Lagoda D. Yu.1ORCID,Suponeva N. A.1ORCID,Piradov M. A.1ORCID

Affiliation:

1. Research Center of Neurology

Abstract

Background. Paired-pulse transcranial magnetic stimulation allows assessing intracortical inhibition. However, a high variability of motor evoked potential (MEP) amplitude is a limitation of its use. Therefore, a new threshold tracking technique became of particular interest, which is based on the measurement not of the amplitude, but of the change of test stimulus intensity required to induce a MEP of a given amplitude.Aim. The assessment of absolute and relative reliability of short-interval intracortical inhibition (SICI) using threshold tracking technique in healthy volunteers.Materials and methods. All healthy volunteers included into the study (n = 12) underwent diagnostic paired-pulse transcranial magnetic stimulation in two consecutive days. The procedure included registration of passive motor threshold; the registration of 30 MEPs with supra-threshold intensity and determination of SICI using threshold tracking technique. At the first day the procedure was performed twice (T1, T2), at the second day – once (T3). Standard error of the measurement (SEM) and SEM% were calculated to assess absolute reliability, and intra-class correlation coefficient – for the assessment of relative reliability.Results. A good or excellent relative reliability were observed for SICI averaged at intervals 1.0–3.0 ms and 1.0–7.0 ms when assessed within a day or at different days. Relative reliability of SICI at separate interstimulus intervals varied in a wide range. SEM% was more than 10 % both for averaged SICI and SICI at all interstimulus intervals. Motor threshold had excellent reliability both assessed within a day and at different days, and low SEM values (5.6 % for Т1–Т2 and 4.39 % for Т1–Т3). High SEM and SEM% were observed for average MEP amplitude, it also had a moderate relative reliability when assessed within a day and a poor one – at different days.Conclusion. Calculation of averaged SICI can be recommended in further studies because of its high reliability values.

Publisher

Publishing House ABV Press

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3