Technique for intraoperative monitoring of corticospinal tract integrity using an electrode with a dynamic balloon

Author:

Krylov V. V.1ORCID,Lukianchikov V. A.1ORCID,Gorozhanin V. A.2ORCID,Barbakadze Z. A.3ORCID,Sinkin M. V.3ORCID

Affiliation:

1. N.I. Pirogov Russian National Research Medical University; Research Center of Neurology; N.V. Sklifosovsky Research Institute of Emergency Medicine, Moscow Healthcare Department

2. Medical Center “UNIKLINIK”

3. N.V. Sklifosovsky Research Institute of Emergency Medicine, Moscow Healthcare Department

Abstract

Aim. To present a technique for continuous monitoring of corticospinal tract integrity using an electrode with a dynamic balloon, examine the advantages and disadvantages of the selected and alternative monitoring techniques.Materials and methods. At the 1st stage, an electrode combined with a dynamic balloon was prepared. At the 2nd stage, continuous monitoring of the corticospinal tract using direct stimulation of the cortex using ballon grid during the main stage of cerebral surgery was performed. At the 3rd stage, interpretation of the obtained neurophysiological responses was performed.Results. The presented technique of continuous monitoring of the integrity of the corticospinal tract through direct cortical stimulation using the developed device prevents false response decreases which significantly helps with the interpretation of the obtained results and increases information value of the technique. The described technique is based on the presented clinical observations of intracerebral tumor resection, as well as microsurgical aneurysm clipping using the technique. During surgery, no false decrease of the neurophysiological signal amplitude was observed due to dynamic ballon inflation and maintenance of close contact between the electrode and the surface of the brain. A surgery performed using this technique allowed to achieve a favorable neurological outcome in a patient in the postoperative period.Conclusion. The presented device allows to perform continuous neuromonitoring using direct cortical electrostimulation with a strip electrode at any level of brain retraction. The technique decreases the risk of primary and secondary injury of the corticospinal and corticobulbar tracts which increases safety of neurosurgical intervention and decreases risks of neurological complications.

Publisher

Publishing House ABV Press

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3