Efficacy of scleral-fixated 3-looped haptics intraocular lens implantation for surgical management of microspherophakia

Author:

Yu Xue-Wen, ,Chen Wei-Jie,Ni Shuang,Lin Xue-Qi,Sheng Si-Ting,Chen Dan,Xu Wen, , , , , ,

Abstract

AIM: To evaluate the safety and efficacy of scleral-fixated 3-looped haptics intraocular lens (IOL) implantation for surgical management of microspherophakia. METHODS: A retrospective case series include 10 microspherophakic patients (15 eyes) who underwent lens removal plus a modified surgical treatment of scleral-fixated 3-looped haptics IOL implantation. The primary outcomes involved visual acuity, intraocular pressure (IOP). Secondary outcomes were spherical equivalent (SE), anterior chamber depth (ACD), corneal endothelial cell density and postoperative complications. RESULTS: After a postoperative follow-up of 17.60±15.44mo, improved visual outcomes can be observed. The uncorrected distance visual acuity (UCVA) logMAR improved from 1.54±0.59 preoperatively to 0.51±0.35 postoperatively (P=0.001), and best corrected visual acuity (BCVA) logMAR improved from 0.97±0.91 preoperatively to 0.24±0.23 postoperatively (P=0.003). Moreover, the SE decreased from -9.58±7.47D preoperatively to -0.65±2.21 D postoperatively (P<0.001). In terms of safety profile, the average IOP decreased from 21.10±12.94 mm Hg preoperatively to 14.03±3.57 mm Hg postoperatively (P=0.044), and the previously elevated IOP of three eyes decreased to the normal range. The ACD increased from 2.25±1.45 mm preoperatively to 3.35±0.39 mm postoperatively (P=0.017). The density of corneal endothelial cells did not change significantly after surgery (P=0.140). The posterior chamber IOLs were well centered and no severe complications were found. CONCLUSION: Lens removal plus the modified surgical treatment of scleral-fixated 3-looped haptics IOL implantation can help in improvement of visual acuity, which can be regarded as a relative safe method for the surgical management of microspherophakia.

Publisher

Press of International Journal of Ophthalmology (IJO Press)

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3