Symmetrical femtosecond laser arc incision in correcting corneal astigmatism in cataract patients

Author:

Hu Zun-Xia, ,Cao Jia-Guo,Ke Yan,Zhang Ying-Ying,Guo Qiong-Tian,He Yu-Ping,Liao Hong-Xia,Tan Xiao,Qin Bo,Li Li, , , , , , , , ,

Abstract

AIM: To evaluate the effect of symmetrical arc incision correcting corneal astigmatism in femtosecond laser-assisted phacoemulsification (FLACS). METHODS: This study enrolled patients with cataract combined with regular corneal astigmatism of >0.75 D, who underwent FLACS. Symmetrical arc incision was set at 8 mm diameter and 85% depth. The follow-up time was 3-24mo (4.92±3.49mo). Pentacam recorded the corneal astigmatism and higher-order aberration at pre-operation and post-operation. The changes in corneal astigmatism were analyzed by Alpins method. The correlation of astigmatism type, age, corneal horizontal diameter, corneal thickness, arc incision length, and correction index (CI) was analyzed, and the residual corneal astigmatism was compared with the residual whole eye astigmatism. RESULTS: Totally 79 patients (102 eyes) were enrolled, 10 patients had corneal epithelial injury, 1 patient occurred corneal epithelial hyperplasia. The corneal astigmatism was 1.23±0.38 D pre-operation, and decreased to 0.76±0.39 D post-operation (t=10.146, P=0.000). Corneal high-order aberration was 0.17±0.08 μm pre-operation and 0.24±0.11 μm post-operation (t=-5.186, P=0.000). The residual corneal astigmatism and residual whole eye astigmatism were no significant difference (t=-0.347, P=0.729). Using Alpin's method, the following were determined: target-induced astigmatism (TIA) =1.23±0.38 D, surgery-induced astigmatism (SIA) =0.77±0.45 D, difference vector (DV)=0.77±0.39 D, and CI=0.54±0.28. Age, astigmatism size, corneal horizontal diameter, corneal thickness, and arc incision length were not correlated with CI. The CI for against the rule astigmatism (ATR) was better than that for with the rule astigmatism (WTR; P=0.001). CONCLUSION: Femtosecond laser-assisted astigmatic keratotomy has better CI of ATR, but increase higher-order corneal aberration. CI is not ideal, it's not a perfect choice if we pursue ideal correction effect.

Publisher

Press of International Journal of Ophthalmology (IJO Press)

Subject

Ophthalmology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Surgical approaches to correct corneal astigmatism at time of cataract surgery: a mini-review;International Journal of Ophthalmology;2024-07-18

2. Effect of low-degree astigmatism on the objective visual quality;International Journal of Ophthalmology;2024-06-18

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3