Refractive outcomes after V4c Toric collamer lens implantation over 1y of follow-up

Author:

,Carreras-Díaz Humberto,Carreras-Díaz María del Rosario, ,Lorente-Velázquez Amalia,

Abstract

AIM: To evaluate refractive outcomes and corneal astigmatism changes after Toric implantable collamer lens with a central port (V4c T-ICL) implantation over 1y of follow-up. METHODS: A retrospective study was performed including 50 eyes of 50 patients that underwent V4c T-ICL implantation. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, refractive and corneal astigmatism changes and corneal coupling correction were evaluated preoperatively, 1 and 12mo postoperatively. Vector analysis was used for astigmatism changes. Coefficient of adjustment (CAdj) was calculated for corneal coupling analysis. RESULTS: The mean UDVA achieved was 0.03 logMAR at 1mo and remained unchanged throughout the whole follow-up (P=0.193). At the last visit, 84% of the eyes achieved a CDVA of 0.00 logMAR or better. Regarding spherical equivalent refraction (SEQ), 96% of eyes were ranges of ±1.00 D and 84% of them within ±0.50 D. Also, 94% of eyes had a remaining refractive cylinder within ±1.00 D and 78% of them within ±0.50 D. Both, SEQ and refractive cylinder, remain stable over the postoperative follow-up (P=1.000 and P=0.660, respectively). In terms of surgically induced astigmatism (SIA), no statistically significant differences were found over the follow-up (P=0.102) and under correction was found with a correction index lower than the unit at each visit. A keratometric astigmatism induced of 0.59±0.53 (vector mean: 0.26×73º) D was reached at the last visit. No significant changes in terms of corneal astigmatism orientation were reported over post-surgery visits (P=0.129 and P=0.097 at 1 and 12mo respectively). No clinical significance was found for CAdj on with-the-rule astigmatism. No postoperative complications resulting from the surgery were found. CONCLUSION: Refractive outcomes suggest that the V4c T-ICL implantation for correction of myopic astigmatism was satisfactory in terms of effectiveness, safety, and stability during 1y of follow-up. Corneal astigmatism induced by the incision around 0.5 D is achieved according to the remaining refractive cylinder found at one-year post-surgery. Corneal coupling analysis results in no unexpected spherical change.

Publisher

Press of International Journal of Ophthalmology (IJO Press)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3