Auto-refraction versus subjective refraction in different phakic and pseudophakic conditions: the Tehran Geriatric Eye Study (TGES)

Author:

Hashemi Hassan, ,Jamali Alireza,Mortazavi Abolghasem,Hashemi Alireza,Khabazkhoob Mehdi, , , ,

Abstract

AIM: To compare the subjective refraction data with non-cycloplegic auto-refraction findings in the geriatric population above 60 years of age according to the different crystalline lens conditions. METHODS: This report is a part of the Tehran Geriatric Eye Study (TGES) that was conducted from January 2019 to January 2020 on elderly population 60 years of age and above in Tehran. The samples were selected by multi-stage stratified random cluster sampling. Of 3791 individual invitees, 3310 (response rate: 87.3%) participated in this study. All study participants underwent non-cycloplegic auto-refraction (auto-refractometer/keratometer Nidek ARK-510) and subjective refraction. RESULTS: Regarding the sphere, eyes with mixed cataract had the worst limits of agreement (LoA: -1.24 to 0.87) and the best agreement was related to the pseudophakic eyes (LoA: -0.83 to 0.54). The highest (0.27±0.31 D) and lowest (0.21±0.27 D) differences between the two methods regarding the cylinder power were observed in eyes with cortical cataract and normal eyes, respectively. The worst LoA between the two methods in measuring the cylinder power was related to the eyes with mixed cataract (LoA: -0.44 to 0.96). Regarding the J0 (horizontal/vertical components of astigmatism), the mean values of J0 obtained by auto-refraction were tended more toward against the rule direction in all crystalline lens conditions, and the two methods had the greatest difference in cortical cataract cases (0.05±0.17 D). Regarding the J45 (oblique components of astigmatism), the lowest (0±0.11 D) and highest (-0.01±0.12 D) differences were observed in normal eyes and eyes with cortical cataract, respectively. CONCLUSION: The auto-refractometer/keratometer Nidek ARK-510 results in the elderly with different phakic and pseudophakic conditions do not correspond well with subjective refraction findings. This discrepancy in spherical findings is more pronounced in individuals with mixed cataract than in other cases.

Publisher

Press of International Journal of Ophthalmology (IJO Press)

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3