Evaluation of a novel deep learning based screening system for pathologic myopia

Author:

Ren Pei-Fang, ,Yu Chen-Ying,Zhu Li-Li,Yang Wei-Hua,Shen Ye, , , ,

Abstract

AIM: To evaluate the clinical application value of the artificial intelligence assisted pathologic myopia (PM-AI) diagnosis model based on deep learning. METHODS: A total of 1156 readable color fundus photographs were collected and annotated based on the diagnostic criteria of Meta-pathologic myopia (PM) (2015). The PM-AI system and four eye doctors (retinal specialists 1 and 2, and ophthalmologists 1 and 2) independently evaluated the color fundus photographs to determine whether they were indicative of PM or not and the presence of myopic choroidal neovascularization (mCNV). The performance of identification for PM and mCNV by the PM-AI system and the eye doctors was compared and evaluated via the relevant statistical analysis. RESULTS: For PM identification, the sensitivity of the PM-AI system was 98.17%, which was comparable to specialist 1 (P=0.307), but was higher than specialist 2 and ophthalmologists 1 and 2 (P<0.001). The specificity of the PM-AI system was 93.06%, which was lower than specialists 1 and 2, but was higher than ophthalmologists 1 and 2. The PM-AI system showed the Kappa value of 0.904, while the Kappa values of specialists 1, 2 and ophthalmologists 1, 2 were 0.968, 0.916, 0.772 and 0.730, respectively. For mCNV identification, the AI system showed the sensitivity of 84.06%, which was comparable to specialists 1, 2 and ophthalmologist 2 (P>0.05), and was higher than ophthalmologist 1. The specificity of the PM-AI system was 95.31%, which was lower than specialists 1 and 2, but higher than ophthalmologists 1 and 2. The PM-AI system gave the Kappa value of 0.624, while the Kappa values of specialists 1, 2 and ophthalmologists 1 and 2 were 0.864, 0.732, 0.304 and 0.238, respectively. CONCLUSION: In comparison to the senior ophthalmologists, the PM-AI system based on deep learning exhibits excellent performance in PM and mCNV identification. The effectiveness of PM-AI system is an auxiliary diagnosis tool for clinical screening of PM and mCNV.

Publisher

Press of International Journal of Ophthalmology (IJO Press)

Subject

Ophthalmology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3