Evaluation of Corvis ST tonometer with the updated software in glaucoma practice

Author:

Halkiadakis Ioannis, ,Gryparis Alexandros,Markopoulos Ioannis,Konstadinidou Vasiliki,Zintzaras Elias,Tzakos Michalis, , , , ,

Abstract

AIM: To evaluate the agreement of biomechanically corrected intraocular pressure (b-IOP) and central corneal thickness (CCT) measurements obtained with the updated Corvis ST tonometer versus Goldmann applanation tonometry (GAT) and optical-based corneal pachymetry (OB-CCT) in controls, patients with ocular hypertension (OHT) and primary open angle glaucoma (POAG). Additionally, we examined the differences in corneal deformation parameters provided by the updated Corvis ST among the three groups. METHODS: For each participant, GAT IOP, OB-CCT and measurements with a Corvis ST with updated software were obtained. Bland-Altman analysis was used to assess the agreement between the two measurement methods. RESULTS: A consecutive series of 80 eyes from 80 participants (30 with POAG, 25 with OHT and 25 normal controls) were included in this prospective study. The mean GAT IOP of all eyes was 17.2±3.6 mm Hg, and the mean b-IOP was 15.9±3.7 mm Hg (Spearman's rho=0.767, P<0.001). The 95% limits of agreement (LoAs) ranged from -3.1 mm Hg to 5.5 mm Hg for GAT IOP and b-IOP. b-IOP was not correlated with OB-CCT (Spearman's rho=-0.13 P=0.917). Meanwhile there was a weak positive corelation between OB-CCT and GAT IOP–b-IOP difference (Spearman's rho=0.378, P=0.001). The mean OB-CCT was 549.5±36.4 µm, and the Corvis-CCT was 556.1±41.5 µm (Spearman's rho=0.900, P<0.001). No statistically significant difference in the new indices provided by the updated Corvis ST was detected among the three groups. Compared with control eyes, POAG eyes had a significantly reduced applanation time 2 after adjusting for OB-CCT and GAT IOP (P=0.048). CONCLUSION: Corvis b-IOP and CCT correlate well with GAT IOP and OB-CCT. b-IOP is not affected by CCT, which might be an advantage, especially in thick or thin corneas. Corvis ST yields shorter applanation time 2 measurements in patients with POAG, which might reflect altered corneal viscoelasticity.

Publisher

Press of International Journal of Ophthalmology (IJO Press)

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3