Effect of an Internal Carotid Stenosis on Orbital Blood Velocity

Author:

Päivänsalo M.1,Riiheläinen K.2,Rissanen T.1,Suramo I.1,Laatikainen L.3

Affiliation:

1. Department of Radiology, Oulu University Hospital, Oulu, Finland

2. Department of Ophthalmology, Oulu University Hospital, Oulu, Finland

3. Department of Ophthalmology, Helsinki University Hospital, Helsinki, Finland

Abstract

Purpose: To examine how an internal carotid artery (ICA) stenosis influences the orbital blood velocity and to determine which velocity parameters are most useful. Material and Methods: the study group comprised 94 randomly selected patients examined with orbital US; most of the patients had a carotid artery stenosis. There were 58 men and 36 women, ranging in age from 22 to 88 years with a mean age of 63.1 years. the ICA stenosis grade was determined with carotid US. Peak systolic (Vp) and end-diastolic blood velocities, systolic acceleration, mean velocity, pulsatile index (PI) and resistance index (RI) were measured within the central retinal artery (CRA) and the ophthalmic artery (OA), and peak velocity was measured within the central retinal vein (CRV). the area under the ROC curve was used to compare the outcome of diagnostic tests. Results: Only a severe (>80%) ICA stenosis decreased orbital blood velocity significantly, while milder stenoses did not cause significant flow decrease or side differences. According to ROC curve analysis, the threshold values giving the highest accuracy in detecting a >80% ICA stenosis were Vp <0.08 cm/s for the CRA and Vp <0.14 cm/s for the OA. the sensitivities for detecting a >80% ICA stenosis were 45% for Vp CRA and 60% for Vp OA. Systolic acceleration also decreased in severe stenoses, but RI, PI and velocity in the CRV did not correlate with ICA pathology. Reversal of OA flow was seen in 92% of ICA occlusion and in 47% of severe ICA stenosis. Conclusion: Orbital Doppler combined with carotid Doppler can be helpful in the diagnosis of the ocular ischaemic syndrome and in the evaluation of whether the symptoms are related to occlusion of the ophthalmic or central retinal vessels or are a consequence of carotid artery stenosis.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3