Breast tomosynthesis: Accuracy of tumor measurement compared with digital mammography and ultrasonography

Author:

Förnvik Daniel1,Zackrisson Sophia2,Ljungberg Otto3,Svahn Tony1,Timberg Pontus1,Tingberg Anders1,Andersson Ingvar2

Affiliation:

1. Department of Medical Radiation Physics, Lund University, Malmö University Hospital, Malmö, Sweden

2. Diagnostic Centre of Imaging and Functional Medicine, Malmö University Hospital, Malmö, Sweden

3. Department of Pathology, Malmö University Hospital, Malmö, Sweden

Abstract

Background: Mammographic tumor size measurement can be difficult because breast structures are superimposed onto a two-dimensional (2D) plane, potentially obscuring the tumor outline. Breast tomosynthesis (BT) is a 3D X-ray imaging technique in which low-dose images are acquired over a limited angular range at a total dose comparable to digital mammography (DM). These low-dose images are used to mathematically reconstruct a 3D image volume of the breast, thus reducing the problem of superimposed tissue. Purpose: To investigate whether breast cancer size can be more accurately assessed with breast tomosynthesis than with digital mammography and ultrasonography (US), by reducing the disturbance effect of the projected anatomy. Material and Methods: A prototype BT system was used. The main inclusion criterion for BT examination was subtle but suspicious findings of breast cancer on 2D mammography. Sixty-two women with 73 breast cancers were included. BT, DM, and US sizes were measured independently by experienced radiologists without knowledge of the pathology results, which were used as reference. Results: The tumor outline could be determined in significantly more cases with BT (63) and US (60) than DM (49). BT and US size correlated well with pathology ( R=0.86 and R=0.85, respectively), and significantly better than DM size ( R=0.71). Accordingly, staging was significantly more accurate with BT than with DM. Conclusion: The study indicates that BT is superior to DM in the assessment of breast tumor size and stage.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 117 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3