Tears of the supraspinatus tendon: assessment with indirect magnetic resonance arthrography in 67 patients with arthroscopic correlation

Author:

Van Dyck P.1,Gielen J. L.1,Veryser J.2,Weyler J.3,Vanhoenacker F. M.4,Van Glabbeek F.5,De Weerdt W.5,Maas M.6,van der Woude H.-J.7,Parizel P. M.1

Affiliation:

1. Department of Radiology, University Hospital Antwerp and University of Antwerp, Antwerp (Edegem), Belgium

2. Department of Radiology, University Hospital Ghent and University of Ghent, Ghent, Belgium

3. Department of Epidemiology and Social Medicine, University of Antwerp, Antwerp (Wilrijk), Belgium

4. Department of Radiology, AZ St-Maarten Duffel/Mechelen, Duffel, Belgium

5. Department of Orthopedics, University Hospital Antwerp and University of Antwerp, Antwerp (Edegem), Belgium

6. Department of Radiology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands

7. Department of Radiology, Onze Lieve Vrouwe Gasthuis, Amsterdam, The Netherlands

Abstract

Background: Magnetic resonance (MR) arthrography is generally regarded as the gold standard for shoulder imaging. As an alternative to direct MR arthrography, the less invasive indirect MR arthrography technique was proposed, offering logistic advantages because fluoroscopic or ultrasonographic guidance for joint injection is not required. Purpose: To assess the diagnostic performance of indirect MR arthrography in the diagnosis of full- and partial-thickness supraspinatus tears in a symptomatic population. Material and Methods: Two radiologists with different levels of experience independently and retrospectively interpreted indirect MR (1.5T) arthrograms of the shoulder obtained in 67 symptomatic patients who underwent subsequent arthroscopy. On MR, the supraspinatus tendon was evaluated for full- or partial-thickness tear. With arthroscopy as the standard of reference, sensitivity, specificity, and diagnostic accuracy of indirect MR arthrography in the detection of full- and partial-thickness tears of the supraspinatus tendon was calculated. Kappa (κ) statistics were used for the assessment of the agreement between arthroscopic and imaging findings and for the assessment of interobserver agreement. Results: For full-thickness tears of the supraspinatus tendon, sensitivities, specificities, and accuracies exceeded 90% for both observers, with excellent interobserver agreement (κ = 0.910). For partial-thickness tears, sensitivities (38–50%) and accuracies (76–78%) were poor for both reviewers, and interobserver agreement was moderate (κ = 0.491). Discrepancies between MR diagnosis and arthroscopy were predominantly observed with small partial-thickness tears. Conclusion: Indirect MR arthrography is highly accurate in the diagnosis of full-thickness rotator cuff tears. However, the diagnosis of partial-thickness tears with indirect MR arthrography remains faulty, because exact demarcation of degenerative change and partial rupture is difficult. On the basis of the above findings, we do not recommend indirect MR arthrography on patients for whom rotator cuff disease is suspected clinically.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 24 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3