Contrast-Enhanced Chest Computed Tomography (CT) Scan with Low Radiation and Total Iodine Dose for Lung Cancer Detection Using Adaptive Statistical Iterative Reconstruction

Author:

Li Xili,Luo Shiyong,Chen Suping,Wang Du,Tan Yiqing

Abstract

Background: Contrast-enhanced chest computed tomography (CT) is useful for the detection and follow-up of patients with lung cancer. However, reaching balance between diagnostic image quality, radiation dose, and iodixanol dose is a cause of concern. Objectives: To investigate the clinical value of adaptive statistical iterative reconstruction (ASIR) in reducing the iodixanol content and radiation dose during contrast-enhanced chest CT scan for patients diagnosed with lung masses/nodules based on the analysis of image quality. Patients and Methods: This prospective study was conducted on 80 patients diagnosed with nodules or masses, who required contrast-enhanced chest CT scans. The experimental group (n = 40) was subjected to iohexol at a high concentration (350 mgI/L) with a tube voltage of 120 kVp and a filter back projection (FBP) reconstruction algorithm. The comparison group (n = 40) was subject to iodixanol at a lower concentration (270 mgI/L) with a tube voltage of 100 kVp and ASIR (blending ratio, 40%). The radiation dose and total iodixanol content, as well as subjective and objective evaluations of image quality, were analyzed and compared. Results: The two groups obtained non-significantly different subjective scores for five structures detected in the lung window and five structures detected in the mediastinal window, as well as the overall image (P > 0.05 for all). Both the two-group images obtained diagnosis-acceptable scores (≥ 3 points) on displays of 10 structures and overall image quality. The mean CT value of vessels (100 kVp vs. 120 kVp: 314.90 ± 23.42 vs. 308.93 ± 21.40; P > 0.05), standard deviation (13.03 ± 0.88 vs. 12.83 ± 0.90; P > 0.05), and contrast-to-noise ratio (20.77 ± 2.20 vs. 20.36 ± 1.94; P > 0.05) were not significantly different between two groups. However, the CT dose index, dose-length product, effective dose, and total iodine dose were reduced by 27.58%, 36.65%, 36.59%, and 22.86% in the 100-kVp group compared to the 120-kVp group. Conclusion: The ASIR showed great potential in reducing the radiation dose and iodine contrast dose, while maintaining good image quality and providing strong confidence for the diagnosis of lung cancer.

Publisher

Briefland

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3