CT-Scan as an Opportunistic Osteoporosis Screening Tool in High-Risk Populations; A Diagnostic Study Conducted on a Sample of Urinary Stone Patients

Author:

Ganji Jameshouran Mohammad AliORCID,Abedi Amir Reza,Montazeri Saeed,Tasharrofi Mohammad Ali,Mansouri Tehrani Mohammad Mersad

Abstract

Background: Osteoporosis is a globally common disorder with significant burdens on the quality of life, and therefore, presents the need for a viable screening tool. Objectives: To establish the diagnostic value of opportunistic computed tomography (CT) scan performed routinely on urinary stone patients for identifying and screening osteoporosis, through measuring vertebral trabecular bone attunement in Hounsfield Units. Patients and Methods: Consecutive subjects were enrolled in this cross-sectional study, who suffered from urinary stones and were undergoing percutaneous nephrolithotomy (PCNL) procedure for stone removal at a tertiary referral hospital. The CT imaging data for the patients were retrospectively extracted, and the patients then underwent a dual energy X-ray absorptiometry (DEXA) scan as the standard protocol in measuring bone mineral density (BMD). CTs were assessed, measuring the bone mineral attenuation at the L1 vertebral level. Diagnostic performance protocols and data comparison with DEXA results were measured. Results: Ninety-two patients were enrolled in the study, 31 (34%) of which were designated as osteoporotic according to standard definitions based on DEXA. Vertebral attunement measurements showed sufficient diagnostic performance, with an area under the curve (AUC) of 0.983 (95% confidence interval [CI], 0.961 – 1.000), 93.55% sensitivity (95% CI, 78.55 – 99.21) and 90.16% specificity (95% CI, 79.81 – 96.30) at the pre-designed 160 Hounsfield units (HU) discriminatory threshold. Conclusion: This study showed that in a high-risk population, vertebral trabecular bone attenuation values retrieved from routine CT imaging holds significant diagnostic value when compared to the gold-standard DEXA, and can be utilized as a viable screening method.

Publisher

Briefland

Subject

Radiology, Nuclear Medicine and imaging

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3