Accuracy of Urinary Etiocholanolone/Androsterone Ratio as Alternative to Serum Testosterone/Dihydrotestosterone Ratio for Diagnosis of 5 Alpha-reductase Type 2 Deficiency Patients and Carriers in Indonesia

Author:

Marzuki Nanis Sacharina,Idris Firman Pratama,Kartapradja Hannie,Renata Shirley,Harahap Alida,Batubara Jose Rizal Latief

Abstract

Background: The 5 Alpha-reductase type 2 deficiency (5ARD2) is an inherited condition, which clinically presents as variable degrees of under virilization in affected 46,XY individuals. In the diagnostic pathway of 5ARD2, the testosterone/dihydrotestosterone (T/DHT) ratio is broadly employed before molecular analysis of the SRD5A2 gene. However, due to cost-benefit considerations, the DHT test in our country is routinely lacking in clinical settings; therefore, we considered applying the urinary etiocholanolone/androsterone (Et/An) ratio as an alternative test. Objectives: We aimed to determine the diagnostic value of the urinary Et/An ratio versus the T/DHT ratio in diagnosing 5ARD2 patients and carriers. Methods: Sixty-six suspected 5ARD2 46,XY disorders of sex development (DSD) individuals and 95 family members were recruited in the study. Their clinical manifestations, T/DHT and urinary Et/An ratios, and SRD5A2 genes were analyzed. Using molecular analysis of the SRD5A2 gene as the gold standard, we compared the accuracy of both ratios in diagnosing 5ARD2 patients and carriers with receiver operating characteristic (ROC) curve analysis. Results: Thirty-seven patients were confirmed molecularly to have 5ARD2, and the rest (n = 29) were assessed as normal controls, while in the carrier group, 53 were molecularly confirmed as carriers and 42 as controls. The AUCs (areas under the curve) of the T/DHT and urinary Et/An ratios were 57.7% (95% CI 43.0 - 72.4%, P > 0.05) and 79.7% (95% CI 69.0 - 90.4%, P < 0.001), respectively, in diagnosing 5ARD2 patients and 54.1% (95% CI 42.4 - 65.8%, P > 0.05) and 75.1% (95% CI 65.1 - 85.1%, P < 0.001), respectively, in diagnosing carriers. The cutoff value of the urinary Et/An ratio was set at ≥ 0.95 for detecting 5ARD2 patients and ≥ 0.99 for detecting carriers. Conclusions: The testosterone/DHT ratio was inaccurate in diagnosing 5ARD2 patients. When molecular analysis for the SRD5A2 gene is lacking, the urinary Et/An ratio may be a useful test to diagnose 5ARD2 patients and carriers.

Publisher

Briefland

Subject

Endocrinology, Diabetes and Metabolism

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3