The Power of Color Flow Doppler Ultrasonography Versus Blind Technique in Localization of Epidural Catheter: A Randomized Prospective Study

Author:

Mahmoud Atef MohamedORCID,Ragab Safaa GaberORCID,Mohamed Agamy TahaORCID,Shaban Goda AbeerORCID

Abstract

Background: The success of epidural analgesia hinges on the precise insertion of the needle within the epidural space; failure rates have been reported to reach 32%. Objectives: We report a new method using color Doppler to help verify the accurate location of the epidural needle tip. Methods: This is a randomized prospective study. Sixty patients undergoing hysterectomy were enrolled, with 30 patients in each group. Color flow Doppler (CFD) ultrasonography was employed to guide epidural catheter placement. The ultrasound-guided epidural technique was used for patients where challenges in identifying traditional landmarks for epidural space localization were anticipated. The procedure commenced with a spinal epidural technique. After sterile preparation and draping of the area, a curvilinear ultrasound transducer, encased in a sterile sheath, was used to locate the interspinous space. The primary outcome measure focused on flow visualization at different insertion levels. Secondary outcome measures included the duration of catheter implantation, intervertebral level of insertion, and dermatome sensory levels. The study also assessed the quality of epidural analgesia and patients' assessment of analgesic quality using a Verbal Numerical Rating Scale. Results: The study reported a successful and predominantly safe outcome, with high success rates in flow visualization and effective anesthesia coverage. Flow visualization at the insertion and surrounding levels demonstrated a 100% success rate at all observed points. The Visual Numeric Rating Scale (VNRS) results indicated a median pain score of 2 with an interquartile range (IQR) of 2 - 3, showcasing a generally low level of post-procedural pain among the subjects, reflecting good quality post-operative analgesia. Regarding dermatome sensory levels after 2 hours, the distribution across various levels, including T4, T6, T7, T8, T10, and T12, exhibited a favorable outcome. The highest proportion was observed at T10 (68.3%), suggesting effective anesthesia coverage in the targeted areas. The study demonstrated comparable efficiency between the CFD-guided and blind techniques in terms of procedural aspects. However, notable distinctions were observed in patients' reported pain levels, with the CFD group experiencing lower pain compared to the blind technique group. Additionally, the study highlighted the association between CFD and improved procedural accuracy and safety. Conclusions: This study advocates for the integration of CFD into routine clinical practice to enhance procedural outcomes and patient safety during hysterectomy surgeries.

Publisher

Briefland

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3