Evaluation of Diagnostic Accuracy of HACOR Score in Predicting the Success Rate of CPAP in Patients with COVID-19-Induced Hypoxemia

Author:

Jahangiri Mehr AzamORCID,Mehri Zahra,Adineh Mohammad,Nematollahzadeh ZohrehORCID

Abstract

Background: In coronavirus disease 2019 (COVID-19)-associated hypoxemic acute respiratory failure (ARF) may require continuous positive airway pressure (CPAP), and having an appropriate criterion for early diagnosis and prediction of CPAP failure or success can significantly reduce the mortality of these patients. Objectives: This study was conducted to evaluate the diagnostic accuracy of heart rate, acidosis, consciousness, oxygenation, and respiratory rate (HACOR) score in predicting the success rate of CPAP in patients with COVID-19 induced hypoxemia. Methods: This retrospective cross-sectional study was conducted on 200 adult patients aged 63.23 ± 16.23 years with mild to moderate acute respiratory failure (COVID-19), partial pressure of oxygen in arterial blood (PaO2) < 300 mmHg, and partial pressure of carbon dioxide in arterial blood (PaCO2) < 45 mmHg from March 21 to November 21, 2021. The patients were admitted to the respiratory intensive care unit (RICU) of Khatam Al-Anbia (PBUH) Hospital in Shoushtar (southwestern Iran) and were subjected to CPAP for respiratory support. The HACOR score was calculated one hour after the CPAP onset. Data were analyzed by SPSS software (version 22) using Kolmogorov-Smirnov, t-test, pair t-tests, receiver operating characteristic (ROC) curve, sensitivity, specificity, and predictive value indices were used to determine the diagnostic performance of the method. The significance level was set at P ≤ 0.05. Results: The mean HACOR score one hour after the onset of CPAP was 3.50 ± 1.57 (P < 0.001), with a mean of 153.84 ± 27.42 mmHg PaO2/fraction of inspired oxygen (FiO2) ratio (P < 0.001). The cut-off point for the HACOR score one hour after CPAP was 5, which had a sensitivity of 98.06% (94.45% - 99.60%) and a specificity of 83.33% (68.64% - 93.03%). Out of 200 patients, 157 patients (78.5%) had CPAP failure, and 43 patients (21.5%) underwent treatment. The diagnostic accuracy values of the HACOR score and PaO2/FiO2 ratio for predicting CPAP failure were 94.92% and 95.96%, respectively. Conclusions: Our findings support that although the HACOR score had a good diagnostic performance in predicting the success rate of CPAP in patients with COVID-19-induced hypoxemia, PaO2/FiO2 ratio was also shown to be a good predictor of success.

Publisher

Briefland

Subject

Rehabilitation,Physical Therapy, Sports Therapy and Rehabilitation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3