Simultaneous Analysis and Efficient Separation of Anabolic Androgenic Steroids in Dietary Supplement by a Validated HPTLC Method

Author:

Saadabadi Zeinab,Daraei Bahram,Kobarfard Farzad,Amirahmadi Maryam,Kheirollahi Kolsum

Abstract

Background: Using sports supplements is common among athletes. The presence of anabolic steroids in sports supplements as a hormonal contaminant can increase production efficiency. Since anabolic steroids cause health problems and result in positive doping tests in athletes, it is important to investigate their presence in the supplement preparations consumed by athletes. Objectives: This paper aims to simultaneously determine ten anabolic steroids by high-performance thin-layer chromatography (HPTLC) method in sports supplements. Methods: Chromatographic analysis was conducted on glass silica gel 60F254 plates. The extracts loaded on silica gel plates are subjected to programed multiple development (PMD) to separate anabolic androgenic steroids (AASs). Densitometric scanning is carried out at the wavelength of 245 and 366nm. The method was validated according to the ICH guidelines. Results: Spots at retardation factor (Rf) 0.72 (elution system 1), 0.4 (elution system 1), 0.29 (elution system 2), 0.25 (elution system 2), 0.1 (elution system 1), 0.65 (elution system 2), 0.59 (elution system 1), 0.44 (elution system 1), 0.8 (elution system 3), and 0.82 (elution system 3) values were recognized as 19-nor androstenedione, 19-nortestosterone, methyl testosterone, clostebol, stanozolol, trenbolone enanthate, oxymetholone, oxandrolone, testosterone enanthate, and nandrolone decanoate, respectively. The linear ranges were 25 - 250 μg/mL for oxymetholone, 7 - 50 μg/mL for 19-nor androstenedione, 19-nortestosterone, and oxandrolone, and 3 - 20 μg/mL for methyl testosterone, clostebol, stanozolol, trenbolone enanthate, testosterone enanthate, and nandrolone decanoate. The developed method is validated by acceptable precision (CV < 20%) and good accuracy (94% < R < 114%). The value of limit of detection (LOD) for all derivatives was in the range of 0.02 - 0.16 μg/spot (20-160 μg/g of supplement), while limit of quantitation (LOQ) was found to be in the range of 0.06 - 0.5 μg/spot (60 - 500 μg/g of supplement). Fifty sports supplement samples as real sample were collected and analyzed. None of the samples screened positive using the HPTLC method. Conclusions: In the present study, the fast, cheap, and simple HPTLC method could be used for the multi-residue analysis of ten anabolic androgenic steroids in sports supplements.

Publisher

Briefland

Subject

Pharmacology (medical),General Pharmacology, Toxicology and Pharmaceutics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3