Measurement of the Optic Nerve Sheath Diameter in Children: Comparison Between Transbulbar Sonography and Magnetic Resonance Imaging

Author:

Steinborn M.1,Fiegler J.1,Ruedisser K.1,Hapfelmeier A.2,Denne C.3,Macdonald E.1,Hahn H.1

Affiliation:

1. Institut für Diagnostische und Interventionelle Radiologie und Kinderradiologie, Städtisches Klinikum München GmbH, Klinikum Schwabing

2. Institut für Medizinische Statistik und Epidemiologie, Technische Universität München

3. Kinderklinik und Poliklinik des Klinikums Rechts der Isar der Technischen Universität München, Kinderklinik Schwabing, Städtisches Klinikum München GmbH, Klinikum Schwabing

Abstract

Abstract Purpose: To evaluate the accuracy of measurements of the optic nerve sheath diameter (ONSD) in children by comparing transbulbar sonography with magnetic resonance imaging (MRI). Materials and Methods: 65 children (age: 3 mo– 17y; mean age: 11.3y) underwent MR imaging of the brain including a heavily T 2-w sequence of the orbit and transbulbar sonography using a 17 MHz linear array transducer. Measurements of the ONSD were performed retrospectively by two experienced readers and all images were evaluated regarding the image quality. Bland-Altman Plots were produced to assess the accuracy of measurements. The correlation between readers and between MR imaging and transbulbar sonography was calculated by the concordance correlation coefficient (CCC). Results: Overall the mean values of the ONSD for MRI (5.86 ± 0.66 mm) and transbulbar sonography (5.86 ± 0.71 mm) were identical. There was a high correlation between readers for measurements of the ONSD both for transbulbar sonography (CCC = 0.93) as well as for MRI (CCC = 0.9). Comparing the measurement values between transbulbar sonography and MRI, the correlation of ONSD values was good to moderate with a high dependency on image quality (CCC [0.31, 0.68]). Conclusion: We were able to demonstrate that the ONSD values of transbulbar sonography in children correlate well with MRI if the relevant anatomic structures are depicted and the measuring points are set correctly. Based on the findings of our study, it seems necessary to define normal and cut-off values for the ONSD in children again to finally assess the clinical relevance of the ONSD as a noninvasive parameter for the evaluation of intracranial pressure.

Publisher

Georg Thieme Verlag KG

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3