Endoscopic ultrasound-guided pancreatic duct intervention and pancreaticogastrostomy using a novel cross-platform technique with small-caliber devices

Author:

Hayat Umar1,Freeman Martin L.1,Trikudanathan Guru1,Azeem Nabeel1,Amateau Stuart K.1,Mallery James1

Affiliation:

1. Division of Gastroenterology, Hepatology and Nutrition, University of Minnesota, Minneapolis, United States

Abstract

Abstract Background and study aims Endoscopic ultrasound (EUS)-guided pancreaticogastrostomy (PG) has been used as an alternative to surgery to drain pancreatic ducts for treatment of disconnected pancreatic duct syndrome (DPDS). Previous techniques involved using needle-knife cautery, bougie dilation or a stent extraction screw to allow stent passage through the gastric wall and pancreatic parenchyma, with potential for severe complications including duct leak, especially if drainage fails. A novel technique employing EUS guided puncture of the main pancreatic duct (MPD) with a 19- or a 22-gauge needle, passage of an 0.018-guidewire, dilation of the tract with a small-diameter (4 F) angioplasty balloon and placement of 3F plastic stents with the pigtail curled inside the duct as an anchor. Methods This is a retrospective case series at a single tertiary center. EUS-guided PG was considered when conventional endoscopic pancreatic duct drainage failed. Main outcomes included technical and clinic success and complications. Results Eight patients underwent PG. Indications were DPDS (n = 4), stenotic pancreaticoenteral anastomosis after Whipple procedure (n = 3) and chronic pancreatitis with dilated MPD (n = 1). Median MPD diameter was 6.75 mm [IQR 2.8 – 7.6]. Technical success was achieved in seven of eight cases (88 %); angioplasty balloon passed into the pancreatic duct in all accessed ducts. There was one asymptomatic duct leak, and no major or delayed complications, with clinical improvement (complete or partial) in five of eight (71 %). Conclusions EUS-guided PG using a small-caliber guidewire, 4F angioplasty balloon, and reverse 3F single pigtail stents offers a safe and atraumatic alternative without use of cautery.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology,Medicine (miscellaneous)

Cited by 24 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3