Diagnosis of A3 Pulley Injuries Using Ultrasound

Author:

Schöffl Isabelle12,Deeg Johannes23,Lutter Christoph4,Bayer Thomas4,Schöffl Volker567

Affiliation:

1. Department of Pediatric and Adolescent Medicine, Klinikum Bamberg, Bamberg, Germany

2. Institute of Anatomy, University Erlangen, Erlangen, Germany

3. Department of Radiology, University Innsbruck, Österreich

4. Department of Radiology, University Erlangen, Erlangen, Germany

5. Department of Sportsmedicine, Department of Orthopedic and Trauma Surgery, Klinikum Bamberg, Bamberg, Germany

6. Department of Trauma Surgery, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, FRG

7. Department of Emergency Medicine, University of Colorado School of Medicine, Denver, USA

Abstract

Abstract Rationale and Objectives Pulley ruptures are the most common injuries in sport climbing. Ruptures of the A2 and A4 pulleys have been studied extensively, and ultrasound has proven to be a highly sensitive and specific tool for their diagnosis. However, the correct diagnosis of A3 pulley ruptures continues to be a challenge. Therefore, we investigated a novel approach to this pathology. Material and Methods Eighteen fingers from nine different human cadavers were examined using high-resolution, dynamic ultrasound before and after being subjected to different combinations of singular and multiple iatrogenic pulley ruptures in a standardised fashion. Special attention was paid to the behaviour of the volar plate (VP) with respect to the proximal interphalangeal joint (PIP) and the flexor tendons before and after pulley rupture. Results Injuries to the A2 and A4 pulleys were diagnosed via ultrasound with sensitivities of 90 % and 94 % and specificities of 100 % and 97 %, respectively. A direct visualisation of the A3 pulley was achieved in 61 % of the fingers. The VP became significantly thicker and shorter during finger flexion as well as after A3 pulley rupture. The distance between tendon and VP became significantly more pronounced after A3 pulley rupture. For distances greater than 0.9 mm between VP and tendon, a sensitivity of 76 % and a specificity of 94 % were achieved for determining A3 pulley ruptures. Conclusion The distance measurement between VP and tendon was found to be a valid indirect method for the diagnosis of A3 pulley ruptures. This approach is the first ultrasound method for accurately diagnosing A3 pulley ruptures.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3