Accuracy Evaluation of Five Blood Glucose Monitoring Systems in Patients from Different Departments

Author:

Li Xiaona1,Zheng Suhua2,Pan Suiyue3,Yan Ting4,Di Jie5,Yang Yinian6,Cheng Jinluo1

Affiliation:

1. Department of Endocrinology, The Affiliated Changzhou No.2 People’s Hospital of Nanjing Medical University, Changzhou, China

2. Department of Hematology and Oncology, The Affiliated Changzhou No.2 People’s Hospital of Nanjing Medical University, Changzhou, China

3. Department of Internal Medicine, The Affiliated Changzhou No.2 People’s Hospital of Nanjing Medical University, Changzhou, China

4. Department of Orthopedics, The Affiliated Changzhou No.2 People’s Hospital of Nanjing Medical University, Changzhou, China

5. Department of Intensive Care Unit, The Affiliated Changzhou No.2 People’s Hospital of Nanjing Medical University, Changzhou, China

6. Department of Nephropathy, The Affiliated Changzhou No.2 People’s Hospital of Nanjing Medical University, Changzhou, China

Abstract

Abstract Background Self-monitoring of blood glucose (SMBG) systems are expected to be accurate and provide reliable results. The international standard ISO (International Organization for Standardization) 15197:2013 is widely accepted for the accuracy evaluation for SMBG systems. Accuracy evaluation was performed for 5 different SMBG systems in patients from multi-departments at the hospital. Method A total of 120 patients from Changzhou Second People’s Hospital (Changzhou, China) were randomized and enrolled in the study. Accuracy evaluation was performed for 5 different SMBG systems: Gold AQ (Sinocare), Freestyle Optium Xceed (Abbott), Contour TS (Bayer), OneTouch Ultra (J&J) and Accu-Chek Performa (Roche). For each system, comparison measurements were performed with YSI 2300 STAT PLUS Glucose and Lactate Analyzer and Roche Cobas 8000 Modular Analyzer. Results All 5 systems showed that 100% of results fall within consensus error grid Zones A and B. Compared with YSI 2300 or Roche Cobas 8000 Modular Analyzer, Gold AQ system showed the highest accuracy. The linearity analysis also showed that Gold AQ had the highest correlation coefficient. Conclusion Compared with other SMBG systems, Gold AQ Glucose Monitoring System manufactured by Sinocare Inc. had the highest accuracy in measuring blood glucose level in patients from multi-departments at this hospital.

Publisher

Georg Thieme Verlag KG

Subject

Endocrinology,General Medicine,Endocrinology, Diabetes and Metabolism,Internal Medicine