Novel Immunochromatographic Test for Anti-factor XIII B Subunit Autoantibodies to Diagnose Autoimmune Acquired Factor XIII Deficiency

Author:

Osaki Tsukasa123,Yokoyama Chikako45,Magari Yasuo6,Souri Masayoshi123,Ichinose Akitada12ORCID

Affiliation:

1. Department of Molecular Patho-Biochemistry and Patho-Biology, Yamagata University School of Medicine, Yamagata, Japan

2. The Japanese Collaborative Research Group (JCRG) on Autoimmune Acquired Coagulation Factor Deficiencies supported by the Japanese Ministry of Health, Labor and Welfare (MHLW), Yamagata, Japan

3. Department of Public Health and Hygiene, Yamagata University School of Medicine, Yamagata, Japan

4. Department of Biochemical Engineering, Graduate School of Science and Engineering, Yamagata University, Yonezawa, Japan

5. Department of Chemistry and Bioengineering, Graduate School of Engineering, Osaka Metropolitan University, Osaka, Japan

6. Q-may Laboratory Corporation, Oita, Japan

Abstract

Autoimmune factor XIII (FXIII) deficiency (AiF13D) is an acquired life-threatening bleeding disorder due to anti-FXIII autoantibodies (autoAbs). We previously established an immunochromatographic test (ICT) for detection of anti-FXIII-A subunit (FXIII-A) autoAbs. Conversely, the detection of anti-FXIII-B subunit (FXIII-B) autoAbs is currently performed in a limited number of medical facilities through time-consuming and expensive laboratory tests, such as dot-blotting analysis and enzyme-linked immunosorbent assay (ELISA). Accordingly, in this study, we generated eight rat monoclonal antibodies (mAbs) against human FXIII-B using the rat lymph node method. By employing an ELISA, two mAbs, 2G12B10 and 8H12B9, were selected considering the distance between the recognition regions of each mAb (the 6th and 9th–10th Sushi domain, respectively) and the strength of their reactivity. Using this mAb combination, we prototyped an ICT to detect anti-FXIII-B autoAbs and distinguish between AiF13D and “nonimmune” acquired FXIII deficiency (acF13D), and tested it with 22 healthy controls, 23 acF13D patients, 15 AiF13D patients without anti-FXIII-B autoAbs, and 8 AiF13D patients with anti-FXIII-B autoAbs. Receiver operating characteristic curve analyses of ICTs for anti-FXIII-B autoAbs were performed and revealed a precision similar to dot-blot analysis. Human anti-FXIII-A mAbs were also generated from a single patient with AiF13D using a new cDNA cloning method, and their binding properties were characterized. Consequently, anti-FXIII-A immunoglobulin G preparations were established as potentially permanent positive controls of ICT for anti-FXIII-A antibodies. Combining the previously developed ICT for anti-FXIII-A autoAbs and the novel ICT for anti-FXIII-B autoAbs may reduce false negatives and lead to appropriate diagnosis and treatment.

Funder

the Japanese Ministry of Education, Culture, Sports, Science and Technology

the Japan Agency for Medical Research and Development

the Japanese Ministry of Health, Labor, and Welfare

Publisher

Georg Thieme Verlag KG

Subject

Hematology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3