Experimental study of loop shape using 0.025-inch ERCP guidewires (with videos)

Author:

Ogura Takeshi1,Ueno Saori1,Okuda Atsushi1,Nishioka Nobu1,Yamada Tadahiro1,Yamada Masanori1,Ueshima Kazuya1,Matsuno Jun1,Yamamoto Yoshitaro1,Higuchi Kazuhide1

Affiliation:

1. 2nd Department of Internal Medicine, Osaka Medical College, Osaka, Japan

Abstract

Abstract Background and study aims Duct penetration by the guidewire sometimes occurs during endoscopic retrograde cholangiography, which might lead to adverse events such as acute pancreatitis. To prevent duct penetration, making a loop shape with the guidewire might provide a useful technique. The aim of this experimental study was thus to evaluate which types of guidewire can most easily form a loop shape. Methods This experimental study evaluated six guidewires (0.025-inch, angle type): MICHISUJI; VisiGlide 2; Jagwire; Pathcorse; RevoWave-α UltraHard 2; and M-through. Flexibility of the tip, shaft stiffness, and the ability to form a loop were evaluated for each type in an ex vivo model. Deformation behavior was also recorded on video, and factors suitable for making a loop shape in each guidewire were evaluated. Results Flexibility and stiffness of each guidewire differed significantly. During an experimental study regrading deformation behavior before forming a loop shape, maximum load was lower for MICHISUJI (6.8 g) than for other guidewires (Jagwire [11.3 g], M-through [12.9 g], VisiGlide 2 [12.9 g], Revowave [21 g], and Pathcorse [25.4 g]). Mean time required to achieve a loop shape was as follows: MICHISUJI, 6.2 seconds; M-through, 8.7 seconds; VisiGlide 2, 11.0 seconds; and Revowave, 7.1 seconds. Conclusion In conclusion, characteristics of flexibility and stiffness among guidewires were significantly different in the ex-vivo study. In the experimental study regrading deformation behavior until achieving a loop shape, maximum load also differed. To evaluate whether guidewires easily form a loop shape, clinical study is needed.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology,Medicine (miscellaneous)

Reference16 articles.

1. Double-guidewire technique in difficult biliary cannulation for the prevention of post-ERCP pancreatitis: a systematic review and meta-analysis;F Tse;Endoscopy,2017

2. Difficult biliary cannulation: use of physician-controlled wire-guided cannulation over a pancreatic duct stent to reduce of precut sphincterotomy (with video);G A Coté;Gastrointest Endosc,2010

3. A prospective randomized study of “covered” versus “uncovered” diamond stents for the management of distal malignant biliary obstruction;H Isayama;Gut,2004

4. Single-session multiple stent deployment using moving cell stent without initial stent mesh to treat malignant hilar biliary obstruction (with videos);T Ogura;J Hepatobiliary Pancreat Sci,2020

5. Current status and issues regarding biliary stenting in unresectable biliary obstruction;T Itoi;Dig Dis Sci,2013

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献