Affiliation:
1. First Department of Orthopedics, Xiaolan People's Hospital of Zhongshan, Zhongshan, China
2. The Second School of Clinical Medicine, Southern Medical University, Guangzhou, China
Abstract
AbstractTo further investigate the biomechanics of a femoral neck system (FNS) for Pauwels type
III femoral fractures based on three different reductions.We constructed three different reduction (anatomical reduction, negative buttress
reduction, and positive buttress reduction) models of Pauwels type III femoral neck
fractures. Then, three cannulated screws (3CS), dynamic hip screws (DHS), dynamic hip screws
combined with an anti-rotation screw (DHS + ARS), one-hole femoral neck system (1HFNS), and
two-hole femoral neck system (2HFNS) were assembled with the reduction models, respectively,
to simulate the internal fixation surgical procedure. All models had a load of 2100 N in
line with the femoral mechanical axis applied. The implant stress, the head and implant
displacements, and the rotational angles of all models were recorded and analyzed.Compared to 3CS and 2HFNS, 1HFNS had higher implant stress (higher than 92.5 MPa and
46.3 MPa, respectively) and displacement (higher than 0.9 mm and 0.8 mm, respectively) in
the anatomical reduction. 2HFNS exhibited the highest stress values (225.5 MPa) in the
anatomical reduction but the lowest values (159.8 MPa) in the positive buttress reduction
when compared to the other implants. 2HFNS showed the best rotational stability in the
negative and positive buttress reduction (rotational angels of 0.8° and 0.6°,
respectively).Based on the outcome of this computational study, it might be concluded that 2HFNS was
an alternative fixation for the treatment of Pauwels type III femoral neck fracture,
especially when anatomical reduction cannot be perfectly attained. More relevant clinical
and biomechanical studies are needed in the future.
Funder
Zhongshan Social Public Welfare and Fundamental Research Projects
Reference20 articles.
1. Hip fracture incidence is decreasing in the high incidence area of Oslo,
Norway;RO Støen;Osteoporos Int,2012
2. Results of internal fixation of Pauwels type-3 vertical femoral neck
fractures;F Liporace;J Bone Joint Surg Am,2008
3. Femoral neck fractures: current management;AV Florschutz;J Orthop Trauma,2015
4. A randomised study in all cervical hip fractures osteosynthesis with Hansson
hook-pins versus AO-screws in 199 consecutive patients followed for two years;J Mjørud;Injury,2006
5. Treatment of femoral neck fractures: sliding hip screw or cannulated screws? A
meta-analysis;Y Xia;J Orthop Surg Res,2021