Orbital Floor Fractures: A Retrospective Review of 45 Cases at a Tertiary Health Care Center

Author:

Rhim Chun H.1,Scholz Thomas1,Salibian Ara1,Evans Gregory R.D1

Affiliation:

1. Aesthetic and Plastic Surgery Institute, University of California at Irvine, Orange, California

Abstract

The purpose of this retrospective study was to investigate treatment options for orbital floor fractures at a Level 1 Trauma Center in Southern California. A review of 45 cases of isolated orbital floor fractures treated at the University of California at Irvine between February 2004 and April 2007 was done. Patients were retrospectively analyzed for gender, age, mechanism of injury, associated facial injuries, presenting symptoms, method of treatment, and postoperative complications. Thirty-six male patients and nine female patients were treated. Motor vehicle collision (26/45) was the most common cause of injury, and the mean age of the patients was 35.5 years (range: 15—81 years). Ecchymosis surrounding the orbital tissue was the most common presentation (38/45). Diplopia was present in 8 of 45 patients, with 1 patient requiring urgent decompression for retrobulbar hematoma. Forty-three patients underwent surgical repair; 40 underwent transconjunctival approach with lateral canthotomy; 17 underwent reconstruction with porous polyethylene Medpor (Porex Surgical, Inc., College Park, GA.); and 26 underwent reconstruction with a titanium mesh plate. Immediate postoperative complications included 12 patients with infraorbital numbness, 3 with diplopia, 1 with cellulitis, and 1 with ectropion with a subcilliary approach. Average timing of surgery of our study was 4.94 days (range, 1—20 days). Orbital floor fracture management has changed significantly over the past few decades with the introduction of new internal fixation methods and new materials for reconstructing orbital floor defects. Recommendations for surgical intervention on orbital floor fractures mostly depend on clinical examination and imaging studies. Consequences of inadequate repair of orbital floor fractures can lead to significant facial asymmetry and visual problems. Both porous polyethylene and titanium plates are effective tools for reconstructing the orbital floor. Our review demonstrates that orbital floor fractures can be repaired safely with minimal postoperative complications and confirms that transconjunctival approach to orbital floor is an effective way for exposure and prevention of ectropion that can be seen with other techniques.

Publisher

SAGE Publications

Subject

Otorhinolaryngology,Oral Surgery,Surgery

Cited by 19 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3