Reproducibility, Repeatability, and Correlation of Central Corneal Thickness Measurement with the Pentacam Scheimpflug System and Ultrasound Pachymetry

Author:

Macias-Rodriguez Yolanda1,Ramos-Dávila Eugenia M.1ORCID,Ruiz-Lozano Raul E.1ORCID,Reyes-Arena Jose V.1,Rivera-Alvarado I. Jocelyn1,Hernandez-Camarena Julio C.1,Rodriguez-Garcia Alejandro1ORCID

Affiliation:

1. Instituto de Oftalmologia y Ciencias Visuales, Tecnologico de Monterrey, Escuela de Medicina y Ciencias de la Salud, Monterrey, Mexico

Abstract

Abstract Background/Aim The importance of an accurate determination of central corneal thickness (CCT) relies on its diagnostic and therapeutic implications in glaucoma, corneal ectasias, corneal edema and endothelial function monitoring, and refractive surgery suitability, among others. We aimed to analyze the repeatability, reproducibility, correlation, and laterality variations of CCT measurements performed with the Pentacam HR and the standard of care ultrasound A-scan (USP). Methods A cross-sectional study including CCT measurements of healthy individuals was performed by three independent examiners with the Pentacam HR and USP. Intra-observer and inter-observer variations were calculated with intra-class correlation coefficients (ICCs). Bland-Altman plots and 95% limits of agreement (95% LoA) were used to assess the agreement between devices. Linear correlation was calculated with Pearsonʼs coefficient. Results Thirty individuals (60 eyes), including 10 (33.3%) men and 20 (66.6%) women, with a mean age of 30.0 ± 9.1 years, were studied. No statistical differences were found in CCT measurements between Pentacam HR (range 500 – 609 µm) and USP (range 498 – 628 µm). There was a high degree of correlation in repeatability and reproducibility of each independent device (ICC > 0.90). Pearsonʼs correlation between 1 vs. 2, 2 vs. 3, and 3 vs. 1 Pentacam HR attempts were 0.914, 0.958, and 0.925, respectively (p < 0.001). Corresponding results for USP were 0.957, 0.957, and 0.943 (p < 0.001). The Pentacam HR tended to overestimate CCT by a mean difference of 3.77 µm (95% LoA, − 24.9 – 18.4). Right eyes were also overestimated (− 3.6 ± 14.1 µm) with the Pentacam HR device, whereas left eyes were underestimated (1.3 ± 11.1 µm). Conclusions The Pentacam HR device provides reliable operator-independent estimates of CCT. Right eyes exhibited a tendency to overestimate with the Pentacam HR. We suspect this difference is due to USP underestimation related to patientsʼ position while performing the study. In clinically relevant scenarios, performing a third measurement and cautiously measuring right eyes can provide higher accuracy.

Publisher

Georg Thieme Verlag KG

Subject

Ophthalmology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3