Detection of aberrant crypt foci with image-enhanced endoscopy

Author:

Kagemoto Kaizo1,Okamoto Koichi1,Takaoka Toshi1,Sato Yasushi1,Kitamura Shinji1,Kimura Tetsuo1,Sogabe Masahiro1,Miyamoto Hiroshi1,Muguruma Naoki1,Tsuneyama Koichi2,Takayama Tetsuji1

Affiliation:

1. Department of Gastroenterology and Oncology, Institute of Biomedical Sciences, Tokushima University Graduate School, Japan

2. Department of Pathology and Laboratory Medicine, Institute of Biomedical Sciences, Tokushima University Graduate School, Japan

Abstract

Abstract Background and study aims Conventional detection of aberrant crypt foci (ACF) with dye-spraying and magnifying observation is labor- and skill-intensive. We performed a prospective non-inferiority study to investigate the utility of image-enhanced endoscopy (IEE) for detection of ACF. Patients and methods Patients with a history of colorectal neoplasm were eligible. The number of ACF in the lower rectum was counted first using IEE magnification with narrow-band imaging (NBI) or blue-laser imaging (BLI), and subsequently using the methylene blue method. The primary endpoint was the ACF detection rate with IEE, i. e., the number of ACF detected with IEE relative to the number of ACF detected with methylene blue. The secondary endpoints were bowel preparation time, ACF detection time, and the detection rate with NBI or BLI. Results A total of 40 patients were enrolled (NBI 20 and BLI 20). The overall detection rate for ACF with IEE was 81.7 % (503/616; 95 %CI 78.8 – 84.6 %), meeting the primary endpoint. The detection rate for ACF with BLI (84.9 %, 258/304) was significantly higher than with NBI (78.5 %, 245/312; P < 0.05). Both bowel preparation time and ACF detection time were significantly shorter with IEE versus the methylene blue method (P < 0.01, respectively). The detection rates for dysplastic and non-dysplastic ACF with IEE were 84.4 % (27/32) and 80.3 % (469/584), respectively. Conclusion IEE is able to detect ACF during colonoscopy with sensitivity non-inferior to that of the conventional methylene blue method. IEE is simpler than the methylene blue method and is therefore a potentially useful new tool for ACF detection.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology,Medicine (miscellaneous)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3