Technical assessment of resolution of handheld ultrasound devices and clinical implications

Author:

Herzog Moritz1ORCID,Arsova Maia2,Matthes Katja2,Husman Julia2,Toppe David1,Kober Julian1,Trittler Tönnis1,Swist Daniel3,Dorausch Edgar Manfred Gustav3,Urbig Antje1,Fettweis Gerhard Paul3,Brinkmann Franz1,Martens Nora1,Schmelz Renate2,Kampfrath Nicole2,Hampe Jochen1

Affiliation:

1. Else Kröner Fresenius Center for Digital Health, TU Dresden Faculty of Medicine Carl Gustav Carus, Dresden, Germany

2. Medical Department 1, University Hospital Dresden, TU Dresden Faculty of Medicine Carl Gustav Carus, Dresden, Germany

3. Vodafone Chair for Mobile Communications, TU Dresden Faculty of Electrical Engineering and Information Technology, Dresden, Germany

Abstract

Abstract Purpose Since handheld ultrasound devices are becoming increasingly ubiquitous, objective criteria to determine image quality are needed. We therefore conducted a comparison of objective quality measures and clinical performance. Material and Methods A comparison of handheld devices (Butterfly IQ+, Clarius HD, Clarius HD3, Philips Lumify, GE VScan Air) and workstations (GE Logiq E10, Toshiba Aplio 500) was performed using a phantom. As a comparison, clinical investigations were performed by two experienced ultrasonographers by measuring the resolution of anatomical structures in the liver, pancreas, and intestine in ten subjects. Results Axial full width at half maximum resolution (FWHM) of 100µm phantom pins at depths between one and twelve cm ranged from 0.6–1.9mm without correlation to pin depth. Lateral FWHM resolution ranged from 1.3–8.7mm and was positively correlated with depth (r=0.6). Axial and lateral resolution differed between devices (p<0.001) with the lowest median lateral resolution observed in the E10 (5.4mm) and the lowest axial resolution (1.6mm) for the IQ+ device. Although devices showed no significant differences in most clinical applications, ultrasonographers were able to differentiate a median of two additional layers in the wall of the sigmoid colon and one additional structure in segmental portal fields (p<0.05) using cartwheel devices. Conclusion While handheld devices showed superior or similar performance in the phantom and routine measurements, workstations still provided superior clinical imaging and resolution of anatomical substructures, indicating a lack of objective measurements to evaluate clinical ultrasound devices.

Funder

Sächsisches Staatsministerium für Wissenschaft und Kunst

Publisher

Georg Thieme Verlag KG

Reference23 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3