Colour Stability of Veneering Composites after Accelerated Aging

Author:

Papadopoulos Triantafillos1,Sarafianou Aspasia2,Hatzikyriakos Andreas3

Affiliation:

1. Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece

2. Department of Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece

3. Department of Prosthodontics, School of Dentistry, Aristotelian University of Thessaloniki, Thessaloniki, Greece

Abstract

Objectives: To investigate the colour stability of four indirect composite restorative materials after accelerated aging.Methods: Four indirect composites (Gradia, Signum+, HFO and Adoro) were used. For each material, six specimens were prepared and subjected to accelerated aging (Suntest CPS+, Atlas, Chicago, IL, USA) according to ISO 7491. A Dr. Lange Microcolor Data Station colorimeter (Braive Instruments, Liege, Belgium) was used to measure specimen colour before and after aging. Measurements were performed according to the CIE L*a*b* system, and the mean L*, a* and b* values for each material were calculated. The equation ΔΕ = [(ΔL*)2 + (Δa*)2 + (Δb*)2]1/2 was used to measure the total colour change (ΔΕ), where ΔL*, Δa* and Δb* are the differences in the respective values before and after aging. One-way ANOVA were used to determine statistically significant differences in ΔL*, Δa*, Δb* and ΔΕ.Results: No statistically significant differences were found in ΔL*, Δa*, Δb* and ΔΕ among the materials tested (PΔL*=.063; PΔa*=.521; PΔb*=.984 and PΔE=.408). After aging, Gradia specimens showed an increase in lightness (ΔL*=0.36) and a green-yellow shift (Δa*=-1.18, Δb*=0.6), while Signum+ specimens exhibited an increase in lightness (ΔL*=0.5) and a green-blue shift (Δa*=-0.9, Δb*=- 0.45). HFO specimens exhibited an increase in lightness (ΔL*=0.75) and a green-yellow shift (Δa*=- 1.3, Δb*=0.06), and Adoro specimens exhibited an increase in lightness (ΔL*=2.07) and a green-yellow shift (Δa*=-1.3, Δb*=0.68).Conclusions: Colour changes were found to be within accepted values of perceptibility and clinical acceptance after accelerated aging, and no statistically significant differences were found in ΔL*, Δa*, Δb* and ΔΕ among the materials tested. (Eur J Dent 2010;4:137-142)

Publisher

Georg Thieme Verlag KG

Subject

General Dentistry

Cited by 13 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3