A Randomized Crossover Comparison of Airway Sealing with the Laryngeal Mask Airway Ambu AuraFlex at Three Intracuff Pressures in Pediatric Laparoscopic Surgery

Author:

Liu Xiang1,Tan Xiaona2,Zhang Qi1,Qiao Li1,Shi Lei1

Affiliation:

1. Department of Anesthesiology, Hebei Medical University Affiliated Children's Hospital of Hebei Province, Shi Jiazhuang, China

2. Department of Neurological Rehabilitation, Hebei Medical University Affiliated Children's Hospital of Hebei Province, Shi Jiazhuang, China

Abstract

Abstract Objective An adequate intracuff pressure is important to ensure sufficient sealing function when using supraglottic airway devices to protect the airway from secretions and achieve adequate positive pressure ventilation. The aim of this study is to analyze a feasible and effective alternative Ambu AuraFlex intracuff pressure in child's laparoscopic surgery. Study Design Seventy-two children were included in this study. After insertion of the laryngeal mask airway AuraFlex, oropharyngeal leak pressure (OLP) was measured at intracuff pressures of 10, 30, and 60-cmH2O according to one of six sequences produced on the basis of 3 × 6 Williams crossover design. During the intraoperative period, AuraFlex was maintained using the last intracuff pressure of the allocated sequence. Oropharyngeal leak pressure, peak airway pressure, the fiberoptic view, mucosal change, and complications were assessed at three intracuff pressures. Results The OLP at the intracuff pressure of 10 cmH2O was significantly lower than that of 30 cmH2O (2# 18.1 ± 1.5 vs. 19.5 ± 1.4 cmH2O, p = 0.001; 2.5# 17.7 ± 1.2 vs. 20.2 ± 1.4, p = 0.001) and 60 cmH2O (2# 18.1 ± 1.5 vs. 20.0 ± 1.3 cmH2O, p = 0.002; 2.5# 17.7 ± 1.2 vs. 20.8 ± 1.1, p = 0.003). Compared with the peak airway pressure in pre-and postpneumoperitoneum, the OLP was significantly higher. Subgroup analysis showed no differences in mucosal change and complications. Conclusion Intracuff pressures of 30 may be sufficient for the Ambu AuraFlex in child's laparoscopic surgery, and there may be no added benefit of an intracuff pressure of 60 cmH2O, as oropharyngeal leak pressures were similar.

Publisher

Georg Thieme Verlag KG

Subject

Obstetrics and Gynaecology,Pediatrics, Perinatology, and Child Health

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3