Abstract

Background The Florida (FL) Sleeve procedure was introduced as a simplified approach for valve-sparing correction of functional Type I aortic insufficiency (AI) associated with aortic root aneurysms. In this study, short- and long-term outcomes after the FL Sleeve procedure were investigated. Methods From May 2002 to January 2016, 177 patients underwent the FL Sleeve procedure. Left ventricular end-diastolic diameter (LVEDD), left ventricular end-systolic diameter, left ventricular ejection fraction, and degree of AI (none = 0, minimal = 1, mild = 2, moderate = 3, severe = 4) were evaluated by echocardiography. Results Mean ± standard deviation of age was 49.41 ± 15.37 years. Survival rate was 98% at 1 year, 97% at 5 years, and 93% at 8 years. Freedom from reoperation was 99% at 1 year and 98% at 2 to 8 years. Three patients (1.69%) died during hospitalization. Three patients (1.69%) developed periprocedural stroke. Postoperative follow-up echocardiography was available in 140 patients at 30 days, and 31 patients at 5 years. AI grade significantly improved from baseline at 30 days (2.18 ± 1.26 vs. 1.1 ± 0.93, p < 0.001) and at 5 years (2.0 ± 1.23 vs. 1.45 ± 0.88, p = 0.04). Preoperative mean LVEDD significantly decreased from 52.20 ± 6.73 to 46.87 ± 8.40 (p < 0.001) at 30 days, and from 53.22 ± 7.07 to 46.61 ± 10.51 (p = 0.01) at 5 years. Conclusions The FL Sleeve procedure is a safe, effective, and durable treatment of aortic root aneurysm and Type I AI. Long-term survival and freedom from reoperation rates are encouraging.

Publisher

Georg Thieme Verlag KG

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3