Three-Dimensional Surface Reconstruction of the Human Cochlear Nucleus: Implications for Auditory Brain Stem Implant Design

Author:

Tarabichi Osama1ORCID,Kanumuri Vivek V.12,Klug Julian13,Vachicouras Nicolas4,Duarte Maria J.1,Epprecht Lorenz1ORCID,Kozin Elliott D.12,Reinshagen Katherine5,Lacour Stéphanie P.4,Brown M Christian12,Lee Daniel J.12

Affiliation:

1. Department of Otolaryngology – Head and Neck Surgery, Massachusetts Eye and Ear Infirmary, Boston, Massachusetts, United States

2. Department of Otology and Laryngology, Harvard Medical School, Boston, Massachusetts, United States

3. Faculty of Medicine, University of Geneva, Switzerland

4. Bertarelli Foundation Chair in Neuroprosthetic Technology, Laboratory for Soft Bioelectronic Interfaces, Centre for Neuroprostheses, École Polytechnique Fédérale de Lausanne (EPFL), Switzerland

5. Department of Radiology, Massachusetts Eye and Ear Infirmary, Boston, Massachusetts, United States

Abstract

Abstract Objective The auditory brain stem implant (ABI) is a neuroprosthesis placed on the surface of the cochlear nucleus (CN) to provide hearing sensations in children and adults who are not candidates for cochlear implantation. Contemporary ABI arrays are stiff and do not conform to the curved brain stem surface. Recent advancements in microfabrication techniques have enabled the development of flexible surface arrays, but these have only been applied in animal models. Herein, we measure the surface curvature of the human CN and adjoining regions to assist in the design and placement of next-generation conformable clinical ABI arrays. Three-dimensional (3D) reconstructions from ultrahigh T1-weighted brain magnetic resonance imaging (MRI) sequences and histologic reconstructions based on postmortem adult human brain stem specimens were used. Design This is a retrospective review of radiologic data and postmortem histologic axial sections. Setting This is set at the tertiary referral center. Participants Data were acquired from healthy adults. Main Outcome Measures The main outcome measures are principal curvature values (Kmin and Kmax) and global radius of curvature. Results The CN was successfully extracted and rendered as a 3D surface in all cases. Significant curvatures of the CN in both histologic and radiographic reconstructions were found with global radius of curvature ranging from 2.08 to 8.5 mm. In addition, local curvature analysis revealed that the surface is highly complex. Conclusion Detailed rendering of the human CN is feasible using histology and 3D MRI reconstruction and highlights complex surface topography that is not recapitulated by contemporary stiff ABI arrays.

Publisher

Georg Thieme Verlag KG

Subject

Neurology (clinical)

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. The Auditory System;From Anatomy to Function of the Central Nervous System;2025

2. Rhombomere 6 r6;The Human Brainstem;2023

3. Brainstem hyperintensity in patients with vestibular schwannoma is associated with labyrinth signal on magnetic resonance imaging but not vestibulocochlear tests;The Neuroradiology Journal;2020-12-16

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3