Abstract Objective To present a three-dimensional (3D)-printed model that simulates endoscopic and exoscopic intracerebral hematoma (ICH) surgery with a tubular retractor. Methods We used 3D printing technology to develop the model that consisted of the skull frame and a replaceable inserted module. Edible gelatin and animal blood were placed into the module to mimic brain tissue and the hematoma. Twenty neurosurgeons were recruited to participate in our training program that required the use of an endoscope and an exoscope to aspirate the hematoma with a tubular retractor. Five postgraduates were asked to complete the entire training with the endoscope five times. Questionnaires were distributed for feedback after the training program. Results The more experienced surgeons obviously performed better than the rather inexperienced surgeons, verifying that our model could reflect the ability of the trainees. As the training progressed, the scores of the postgraduates increased, and the average score of the fifth training was obviously higher than the first score. No significant differences were observed in the trainees' performance with the endoscope and the exoscope. The feedback questionnaires showed the average score for value of the simulator as a training tool was a 3.65 (on a 4-point scale). Our model received better comments regarding the bone texture (mean: 3.20), the brain tissue texture (mean: 3.20), and the experience in aspirating the hematoma (mean: 3.10). The surgical position (mean: 2.95), surgical approach (mean: 2.90), and simulated brain tissue (mean: 2.85) should be improved. Conclusion Our model was practical for endoscopic and exoscopic ICH surgery training. The results of our program showed that prior surgical experience benefited the mastery of both the endoscopic and the exoscopic ICH surgery in the 3D-printed model. Our model could make mastering basic skills more efficient.

Publisher

Georg Thieme Verlag KG

Subject

Clinical Neurology,Surgery

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3